Table 4-1. partial availability conditions -9 – HP Surestore 6.140 Tape Library User Manual
Page 115
Understanding Errors and Troubleshooting
Understanding Error States
Chapter 4
4-9
E
rr
o
rs
&
T
roub
le
sh
oo
ti
ng
Table 4-1
Partial Availability Conditions
Library Status
Cause
Solution
Date and time not
set
The date and time is not set on
the front panel.
• Set the date and time. (See
“Setting the Date and Time” on
page 3-22.)
Drive not present
The library could not detect all
expected drive modules.
NOTE: This typically occurs
because a drive was physically
removed from the library. This
may also occur for a brief time
during an online drive repair.
This condition will persist over a
power cycle.
If a drive is present in the library:
• Power off the library.
• Reseat the drive module.
• Power on the library.
• Contact your service
representative.
Drive offline
Drive(s) taken offline because of
the following:
• Taken offline from front
panel, host computer, or
library controller.
• Drive(s) failed power-on test.
• Drive module board failed
power-on test.
• Failed serial communication
to drive.
• Failed to load/unload tape.
• Verify that the drive is online.
If not, put drive back online
from the front panel.
• Power cycle the library.
• Verify cabling and termination.
• Check the error log from the
front panel or RMC Web-Based
Library Administrator pages
for possible causes.
• Contact your service
representative.
Drive online
pending
Drive(s) are present and
powered up, but have outdated
firmware.
• Update drive firmware.
(See page 4-60.)
Drive firmware
mismatch
Drives are present and powered
up, but have different revisions
of firmware.
• Update drive firmware.
(See page 4-60.)
Drive needs
cleaning
One or more drives need
cleaning.
• Clean the drive(s). (See page 2-
15.)