Failback preference setting for HSV controllers

Table 25 (page 62)

describes the failback preference behavior for the controllers.

Table 25 Failback preference behavior

Behavior

Point in time

Setting

The units are alternately brought online to
Controller A or to Controller B.

At initial presentation

No preference

If cache data for a LUN exists on a particular
controller, the unit will be brought online there.

On dual boot or controller resynch

Otherwise, the units are alternately brought
online to Controller A or to Controller B.

All LUNs are brought online to the surviving
controller.

On controller failover

All LUNs remain on the surviving controller.
There is no failback except if a host moves the
LUN using SCSI commands.

On controller failback

The units are brought online to Controller A.

At initial presentation

Path A - Failover Only

If cache data for a LUN exists on a particular
controller, the unit will be brought online there.

On dual boot or controller resynch

Otherwise, the units are brought online to
Controller A.

All LUNs are brought online to the surviving
controller.

On controller failover

All LUNs remain on the surviving controller.
There is no failback except if a host moves the
LUN using SCSI commands.

On controller failback

The units are brought online to Controller B.

At initial presentation

Path B - Failover Only

If cache data for a LUN exists on a particular
controller, the unit will be brought online there.

On dual boot or controller resynch

Otherwise, the units are brought online to
Controller B.

All LUNs are brought online to the surviving
controller.

On controller failover

All LUNs remain on the surviving controller.
There is no failback except if a host moves the
LUN using SCSI commands.

On controller failback

The units are brought online to Controller A.

At initial presentation

Path A -
Failover/Failback

If cache data for a LUN exists on a particular
controller, the unit will be brought online there.

On dual boot or controller resynch

Otherwise, the units are brought online to
Controller A.

All LUNs are brought online to the surviving
controller.

On controller failover

All LUNs remain on the surviving controller.
After controller restoration, the units that are

On controller failback

online to Controller B and set to Path A are
brought online to Controller A. This is a one
time occurrence. If the host then moves the LUN
using SCSI commands, the LUN will remain
where moved.

The units are brought online to Controller B.

At initial presentation

Path B -
Failover/Failback

62

Enterprise Virtual Array operation