1.1.03.03 INFORMATION condition—Overrun recovery

This condition report notes automatic recovery initiated by the occurrence of too many data overruns
with respect to received messages on the CAN bus. This condition report remains active until one
of the following occurs:

90 seconds elapses

The CURRENT ALARM QUEUE is read via SES

The RECENT ALARM LOG is read via SES

No action is required.

Voltage sensor and current sensor conditions

The format of these sensor condition reports is 1.2.en.ec for a voltage sensor, and 1.3.en.ec for
a current sensor, where:

1.2. is the voltage sensor element type

1.3. is the current sensor element type number

en. is the sensor element number

ec is the error code

Table 44 (page 131)

lists the location of the power supply voltage and current sensors.

Table 44 Voltage and current sensor locations

Sensor Element Location

Sensor

Power Supply 1 +5 VDC

01.

Power Supply 1 +12 VDC

02.

Power Supply 2 +5 VDC

03.

Power Supply 2 +12 VDC

04.

Use HP P6000 Command View to view the voltage and current error thresholds for both +5 VDC
and +12 VDC power supplies.

1.2.en.01 NONCRITICAL condition—High voltage

This condition report indicates that an element voltage is approaching, but has not reached, the
high voltage CRITICAL threshold. Continued operation under these conditions may result in a
CRITICAL condition. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your
HP-authorized service representative.

1.2.en.02 CRITICAL condition—High voltage

This condition report indicates that an element voltage has reached the high voltage CRITICAL
threshold. This report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your
HP-authorized service representative.

1.2.en.03 NONCRITICAL condition—Low voltage

This condition report indicates that an element voltage is approaching, but has not reached, the
low voltage CRITICAL threshold. Continued operation under these conditions may result in a
CRITICAL condition. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your
HP-authorized service representative.

Correcting errors