beautypg.com

En.04 critical condition—low voltage, En.01 noncritical condition—high current, En.02 critical condition—high current – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual

Page 132: Backplane conditions, 10 noncritical condition—backplane nvram read, 13 noncritical condition—backplane wwn is blank

background image

1.2.en.04 CRITICAL condition—Low voltage

This condition report indicates that an element voltage has reached the low voltage CRITICAL
threshold. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your
HP-authorized service representative.

1.3.en.01 NONCRITICAL condition—High current

This condition report indicates that an element current is approaching, but has not reached, the
high current CRITICAL threshold. Continued operation under these conditions may result in a
CRITICAL condition. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your
HP-authorized service representative.

1.3.en.02 CRITICAL condition—High current

This condition report indicates that an element current has reached the high current CRITICAL
threshold. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your
HP-authorized service representative.

Backplane conditions

IMPORTANT:

Backplane

NVRAM errors usually occur during manufacture. At this time they are

identified and corrected. They rarely occur during normal operation.

The format of a

backplane

condition report is 8.2.01.ec, where:

8.2. is the

backplane

element type number

01. is the two-character

backplane

element number

ec is the error code

The only corrective action available for this error is to replace the drive enclosure.

8.2.01.10 NONCRITICAL condition—Backplane NVRAM read

An invalid NVRAM read occurred and an automatic recovery process has begun. This condition
report is active for 15 seconds.
If the automatic recovery process does not correct the problem, record all six characters of the
condition report, then contact your HP-authorized service representative.

8.2.01.11 NONCRITICAL condition—Backplane NVRAM write failure

The system is unable to write data to the NVRAM. This problem prevents communication between
elements in the enclosure. This condition report is active for 15 seconds.
To correct this problem, record all six characters of the condition report, then contact your
HP-authorized service representative.

8.2.01.12 NONCRITICAL condition—Backplane NVRAM read failure

The system is unable to read data from the NVRAM. This problem prevents communication between
elements in the enclosure. This condition report is active for 15 seconds.
To correct this problem, record all six characters of the condition report, then contact your
HP-authorized service representative.

8.2.01.13 NONCRITICAL condition—Backplane WWN is blank

The system is unable to read valid data from the NVRAM. This report is active until corrected. This
condition can result in incorrect device location data being displayed.

132

EMU-generated condition reports