Shutting the controller down

Use the following procedure to access the Shutdown System display and execute a shutdown
procedure.

CAUTION:

If you decide NOT to power off while working in the Power Off menu, Power Off

System NO must be displayed before you press Esc. This reduces the risk of accidentally powering
down.

NOTE:

HP P6000 Command View offers the preferred method for shutting down the controller.

Shut down the controller from the OCP only if HP P6000 Command View cannot communicate
with the controller.

Shutting down the controller from the OCP removes power from the controller on which the procedure
is performed only. To restore power, toggle the controller’s power.

1.

Press

three times to scroll to the Shutdown Options menu.

2.

Press

to display Restart.

3.

Press

to scroll to Power Off.

4.

Press

to select Power Off.

5.

Power off system is displayed. Press Enter to power off the system.

Restarting the system

To restore the controller to an operational state, use the following procedure to restart the system.
1.

Press

three times to scroll to the Shutdown Options menu.

2.

Press

to select Restart.

3.

Press

to display Restart system?.

4.

Press Enter to go to Startup.

No user input is required. The system will automatically initiate the startup procedure and
proceed to load the Storage System Name and World Wide Name information from the
operational controller.

Uninitializing the system

Uninitializing the system is another way to shut down the system. This action causes the loss of all
storage system data. Because HP P6000 Command View cannot communicate with the disk drive
enclosures, the stored data cannot be accessed.

CAUTION:

Uninitializing the system destroys all user data. The WWN will remain in the controller

unless both controllers are powered off. The password will be lost. If the controllers remain powered
on until you create another storage system (initialize via GUI), you will not have to re-enter the
WWN.

Use the following procedure to uninitialize the system.
1.

Press

three times to scroll to the Shutdown Options menu.

2.

Press

to display Restart.

3.

Press

twice to display Uninitialize System.

4.

Press

to display Uninitialize?

5.

Select Yes and press Enter.

The system displays Delete all data? Enter DELETE:_______

48