HP 4000.6000.8000 Enterprise Virtual Arrays User Manual
Page 115
This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For
example, if you are using 10K RPM drives, the power specifications will be approximately 20% less than the 15K RPM
drives.
Table 39 EVA6x00 power specifications — 230 Volts
2C8D
2C7D
2C6D
2C5D
2C4D
Specification
3344
2967
2590
2214
1837
Total System
Wattage
Typical
1
11409
10124
8838
7553
6268
Total System
BTU/hour
7.9
7.0
6.1
5.2
4.3
Input Current (A) -
Typical per line
403
357
311
272
244
In Rush Current (A)
13.3
11.9
10.0
8.8
7.3
Input Current (A) -
Maximum per line
Failover Mode
1
Typical is described as a system in normal steady state operation. (i.e., both PDUs operating normally, the array
reading/writing to disk drives in a production environment).
This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For
example, if you are using 10K RPM drives, the power specifications will be approximately 20% less than the 15K RPM
drives.
Table 40 EVA8x00 power specifications — 208 Volts
2C12D
2C10D
2C8D
2C6D
2C2D
Specification
4920
4167
3414
2660
1153
Total System
Wattage
Typical
1
16789
14218
11648
9077
3936
Total System
BTU/hour
12.3
10.4
8.5
6.7
2.9
Input Current (A) -
Typical per line
528
451
363
280
132
In Rush Current (A)
20.8
17.7
14.5
11.3
4.9
Input Current (A) -
Maximum per line
Failover Mode
1
Typical is described as a system in normal steady state operation. (i.e., both PDUs operating normally, the array
reading/writing to disk drives in a production environment).
This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For
example, if you are using 10K RPM drives, the power specifications will be approximately 20% less than the 15K RPM
drives.
Table 41 EVA8x00 power specifications — 230 Volts
2C12D
2C10D
2C8D
2C6D
2C2D
Specification
4920
4167
3414
2660
1153
Total System
Wattage
Typical
1
16789
14218
11648
9077
3936
Total System
BTU/hour
11.6
9.8
8.1
6.3
2.7
Input Current (A) -
Typical per line
586
500
403
311
147
In Rush Current (A)
19.7
16.7
13.7
10.6
4.6
Input Current (A) -
Maximum per line
Failover Mode
Storage system specifications
115