Iscsi connection configurations, Fabric connect iscsi, Direct connect iscsi – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual
Page 14: Fabric connect iscsi direct connect iscsi
iSCSI connection configurations
The EVA4x00/6x00/8x00 support iSCSI attach configurations using the HP MPX100. Both fabric
connect and direct connect are supported for iSCSI configurations. For complete information on
iSCSI configurations, go to the following website:
NOTE:
An iSCSI connection configuration supports mixed direct connect and fabric connect.
Fabric connect iSCSI
Fabric connect provides an iSCSI solution for EVA Fibre Channel configurations that want to
continue to use all EVA ports on FC or if the EVA is also used for HP P6000 Continuous Access.
Make sure the following requirements are met when configuring your MPX100 environment for
fabric connect:
•
A maximum of two MPX100s per storage system are supported
•
Each storage system port can connect to a maximum of two MPX100 FC ports.
•
Each MPX100 FC port can connect to a maximum of one storage system port.
•
In a single MPX100 configuration, if both MPX100 FC ports are used, each port must be
connected to one storage system controller.
•
In a dual MPX100 configuration, at least one FC port from each MPX100 must be connected
to one storage system controller.
•
The Host Port Configuration must be set to Fabric Connect using the OCP.
•
HP P6000 Continuous Access is supported on the same storage system connected in MPX100
fabric connect configurations.
Direct connect iSCSI
Direct connect provides a lower cost solution for configurations that want to dedicate controller
ports to iSCSI I/O. When using direct connect, the storage system controllers are connected directly
to the MPX100(s), not to SAN Fibre Channel switches.
Make sure the following requirements are met when configuring your MPX100 environment for
direct connect:
•
A maximum two MPX100s per storage system are supported.
•
In a single MPX100 configuration, if both MPX100 FC ports are used each port must be
connected to one storage system controller.
•
In a dual MPX100 configuration, at least one FC port from each MPX100 must be connected
to one storage system controller.
•
The Host Port Configuration must be set to Direct Connect using the OCP.
•
HP P6000 Continuous Access cannot be used with direct connect configurations.
•
EVAs cannot be directly connected to each other to create an HP P6000 Continuous Access
configuration. However, hosts can be directly connected to the EVA in an HP P6000 Continuous
Access configuration. At least one port from each array in an HP P6000 Continuous Access
configuration must be connected to a Fabric connection for remote array connectivity.