En.06 unrecoverable condition—no blowers installed, Temperature conditions, En.01 noncritical condition—high temperature – HP 4000.6000.8000 Enterprise Virtual Arrays User Manual
Page 123
![background image](/manuals/396690/123/background.png)
0.3.en.06 UNRECOVERABLE condition—No blowers installed
NOTE:
IMPORTANT
When this condition exists there will be two error messages.
The first message will be 0.3.en.05 and will identify the first
.
The second message will be 0.3.en.06 and will identify the second
.
The EMU cannot detect any installed
. Shutdown is imminent! The EMU will shut down the
enclosure in seven minutes unless you correct the problem. This condition report remains active
until you correct the problem or the EMU shuts down the power supplies, whichever occurs first.
Complete the following procedure to correct this problem.
1.
Record all six characters of the condition report.
2.
Use the controller shutdown procedure to shut down the controllers.
3.
Contact your authorized service representative.
CAUTION:
An automatic shutdown and possible data corruption may result if the
is
removed before a replacement is available.
Temperature conditions
The format of a temperature condition report is 0.4.en.ec, where:
•
0.4. is the temperature sensor element type
•
en. is the two-character temperature sensor element
•
ec is the error code
See
to determine the location of each temperature sensor.
Table 43 Temperature sensor element numbering
Sensor location
Sensor
Sensor location
Sensor
Drive Bay 7
10.
Power Supply 1 Exhaust
01.
Drive Bay 8
11.
Power Supply 2 Exhaust
02.
Drive Bay 9
12.
EMU
03.
Drive Bay 10
13.
Drive Bay 1
04.
Drive Bay 11
14.
Drive Bay 2
05.
Drive Bay 12
15.
Drive Bay 3
06.
Drive Bay 13
16.
Drive Bay 4
07.
Drive Bay 14
17.
Drive Bay 5
08.
Drive Bay 6
09.
The following sections list the temperature condition reports and the default temperature thresholds.
Use HP P6000 Command View to view the temperature sensor ranges for the disk drives, EMU,
and power supplies.
0.4.en.01 NONCRITICAL condition—High temperature
This condition report indicates that an element temperature is approaching, but has not reached,
the high temperature CRITICAL threshold. Continued operation under these conditions may result
in a CRITICAL condition. This condition report remains active until the problem is corrected.
Complete the following procedure to correct this problem.
1.
Record all six characters of the condition report.
2.
Ensure that all elements are properly installed to maintain proper air flow.
Correcting errors