2 Enterprise Virtual Array hardware components

The Enterprise Virtual Array includes the following hardware components:

Fibre Channel drive enclosure — Contains disk drives, power supplies, blowers, I/O modules,
and an Environmental Monitoring Unit (EMU).

Fibre Channel loop switches — Provides twelve-port central interconnect for Fibre Channel
drive enclosure FC Arbitrated Loops. The loop switches are required for EVA6000/6100 and
EVA8000/8100 configurations with more than four disk enclosures.

HSV controller — Manages all aspects of storage system operation, including communications
between host systems and other devices. A pair of HSV controllers is included in the Enterprise
Virtual Array.

Rack — A variety of free-standing racks are available.

Physical layout of the storage system

The basic physical components are shown in

Figure 5 (page 19)

. The disk drives are installed in

the disk enclosures, which connect to Fibre Channel loop switches, except on the EVA4000/4100
which does not use switches. The controller pair also connects to the loop switches.

Figure 5 Storage system hardware components

1. controllers

2. loop switches

3. disk enclosures

The EVA8000/8100, EVA6000/6100, and EVA4000/4100 are available as follows:

EVA8000/8100 — available in multiple configurations ranging from the single-rack 2C2D
configuration to the multi-rack 2C18D. The EVA8000 includes two HSV210-A controllers and
four Fibre Channel loop switches. The EVA8100 includes two HSV210-B controllers and four
Fibre Channel loop switches.

EVA6000/6100 — available in configurations ranging from the 2C4D configuration to the
2C8D configuration. The EVA6000 includes two HSV200-A controllers and two Fibre Channel

Physical layout of the storage system

19