Figure 3 EVA4000/4100 configuration

7 Fabric 2

1 Network interconnection

8 Controller A

2 Management server

9 Controller B

3 Non-host

10 Cache mirror ports

4 Host X

11 Drive enclosure 1

5 Host Z

12 Drive enclosure 2

6 Fabric 1

Direct connect

NOTE:

Direct connect is currently supported on Microsoft Windows only. For more information

on direct connect, go the Single Point of Connectivity Knowledge (SPOCK) at:

http://www.hp.com/

storage spock

.

Direct connect provides a lower cost solution for smaller configurations. When using direct connect,
the storage system controllers are connected directly to the host(s), not to SAN Fibre Channel
switches. Make sure the following requirements are met when configuring your environment for
direct connect:

A management server running HP P6000 Command View must be connected to one port on
each EVA controller. The management host must use dual HBAs for redundancy.

To provide redundancy, it is recommended that dual HBAs be used for each additional host
connected to the storage system. Using this configuration, up to four hosts (including the
management host) can be connected to an EVA8x00, and up to two hosts can be connected
to an EVA6x00 or EVA4x00.

The Host Port Configuration must be set to Direct Connect using the OCP.

HP P6000 Continuous Access cannot be used with direct connect configurations.

The HSV controller firmware cannot differentiate between an empty host port and a failed
host port in a direct connect configuration. As a result, the Connection state dialog box on
the Controller Properties window displays Connection failed for an empty host port. To fix this
problem, insert an optical loop-back connector into the empty host port; the Connection state
will display Connected. For more information about optical loop-back connectors, contact
your HP-authorized service provider.