Table 33 Environmental specifications (continued)

10% to 90% non-condensing

Humidity

5% to 90% non-condensing

Shipping Humidity

Up to 8,000 ft. (2,400 m)

Altitude

Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger

Air Quality

Power specifications

The input voltage is a function of the country-specific input voltage to Enterprise storage system
rack power distribution units (PDUs).

Table 34 (page 113)

defines the AC input power available to

the drive enclosure power supplies.

CAUTION:

The AC power distribution within a rack ensures balance to each PDA and reduces

the possibility of an overload condition. Changing the cabling to or from a PDM could cause an
overload condition.

Table 34 Enterprise storage system AC input line voltages

Maximum

Nominal

Minimal

Specification

60 Hz service

63 Hz

60 Hz

57 Hz

AC Line Voltage

220 VAC

202 VAC

180 VAC

AC Line Voltage—Japan

220 VAC

208 VAC

180 VAC

AC Line Voltage–North America

254 VAC

240 VAC

208 VAC

AC Line Voltage–Europe

50 Hz service

53 Hz

50 Hz

47 Hz

AC Line Frequency

220 VAC

202 VAC

180 VAC

AC Line Voltage–Japan

235 VAC

220 VAC

190 VAC

AC Line Voltage–North America

244 VAC

230 VAC

200 VAC

AC Line Voltage–North America

254 VAC

240 VAC

208 VAC

AC Line Voltage–Europe

Table 35 Power Data (North America/Europe/Japan) maximum configuration

North America – 3 wire NEMA No. L6-30P, 30 amp (208 to 240V 50–60Hz 30A)
Europe – 3 wire, 2 pole IEC 309, 30 amp, (220 to 240V 50Hz 32A)

AC plug type (quantity 2)

Single

Number of phases

17A @ 200V-240V AC, 60Hz total, 4.25 A per power cord

Rated current

North America – 208 or 230V
Europe – 230V

Nominal Line Voltage

Japan – 206V

187 to 256V

Range Line Voltage

North America 60Hz, Europe 50Hz, Japan 50 or 60 Hz

Line Frequency

Storage system specifications