Using g4 web control to interact with a g4 panel – AMX Modero NXD-CV5 User Manual
Page 57
Configuring Communication
45
NXD-CV5 5" Modero Wall/Flush Mount Touch Panel
Using G4 Web Control to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4 enabled panel via the web. This
feature works in tandem with the new browser-capable NetLinx Security firmware update (build 300 or
higher). G4 Web Control is only available with the latest Modero panel firmware.
Refer to the G4 Web Control Page section on page 70 for more detailed field information.
1.
Press the grey Front Setup Access button for 3 seconds to open the Setup page.
2.
Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup
page and display an on-screen keypad.
3.
Enter 1988 into the Keypad’s password field (1988 is the default password).
4.
Press Done when finished.
5.
Press the G4 WebControl button to open the G4 Web Control page (FIG. 42).
6.
Press the Enable/Enabled button until it toggles to Enabled (light blue color).
7.
The Network Interface Select field is read-only and displays the method of communication to the web.
Verify you have selected the proper interface connection as this field does not auto-detect the
connection type being used (see below).
Wired is used when a direct Ethernet connection is being used for communication to the web. This
is the default setting if either no wireless interface card is detected or if both an Ethernet and
wireless card connection is detected by the panel.
Wireless is used when a wireless card is detected within the internal card slot. The CV5 panel does
not provide wireless communication and therefore this option is not available.
8.
Press the Web Control Name field to open the Web Name keyboard.
9.
From the Web Name keyboard, enter a unique alpha-numeric string to identify this panel. This
information is used by the NetLinx Security Web Server to display on-screen links to the panel. The on-
screen links use the IP Address of the panel and not the name for communication (FIG. 43).
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from www.amx.com. Refer to your NetLinx Master instruction
manual for more detailed information on the use of the new web-based NetLinx
Security.
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
FIG. 42
G4 Web Control page