Configuring Communication
43
NXD-CV5 5" Modero Wall/Flush Mount Touch Panel
17.
Click Done to accept the new value and return to the System Connection page.
18.
Do not alter the Master Port Number value (this is the default value used by NetLinx).
19.
Press the Back button to open the Protected Setup page.
20.
Press the on-screen Reboot button to both save any changes and restart the panel.
Master Connection section - NetLinx Master Ethernet IP Address - URL Mode
In this mode, enter the System Number (zero for an unknown System Number) and the IP/URL of the Master
(Master Port Number is defaulted to 1319).
1.
Press the blue Type field (from the Master Connection section) until the choice cycles to the word
Ethernet (FIG. 40). Refer to the System Settings Page section on page 68 for more information about the
fields on this page.
2.
Press the Mode field until the choice cycles to the word URL.
By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value
directly from the communicating target Master (virtual or not). A Virtual Master system value can be set
within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.
3.
Press the Master IP/URL field to open a Keyboard and enter the Master IP Address (obtained from the
Diagnostics - Networking Address dialog of the NetLinx Studio application).
4.
Click Done to accept the new value and return to the System Connection page.
5.
Do not alter the Master Port Number value (this is the default value used by NetLinx).
6.
Enter a username and password (into their respective fields) if the target Master has been previously
secured.
7.
Press the Back button to open the Protected Setup page.
8.
Press the on-screen Reboot button to both save any changes and restart the panel.
Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode
In this mode, you must add the Modero panel IP Address into the URL List of the Master (using NetLinx
Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from
its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP Address
from the IP Settings of the System Connection page.
The DHCP/Static field (in the IP Settings section of the System Connection page) must be set to
DHCP to get Dynamic IP information for the panel.
Press the on-screen Reboot (from the Protected Setup page) to both save any changes and restart
the panel.
After power-up, press the grey Front Setup Access button for 3 seconds to access the Setup page.
Navigate to the Setup > Protected Setup > System Connection page and note the newly obtained
Dynamic IP Address information from the IP Settings section. This information is then entered into
the URL List for the connected NetLinx Master.
2.
Toggle the Type field until Ethernet is selected (from the Master Connection section of the System
Connection page).
3.
Press the Mode field (to set the connection Mode) until the choice cycles to the word Listen. The System
Number and Master IP/URL fields are then greyed-out.
4.
Enter a username and password (into their respective fields) if the target Master has been previously
secured.
5.
Select the OnLine Tree tab from the Workspace window.
6.
Select Diagnostics > URL Listing from the Main menu (FIG. 41).
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number (from
within the Device Addressing dialog) is correctly assigned.