AMX Modero NXD-CV5 User Manual
Page 29
Installation
17
NXD-CV5 5" Modero Wall/Flush Mount Touch Panel
1.
Rest the right Stud Mounting tabs onto the stud (keeping the knockouts on the left). Be sure to leave
enough of a gap between the stud and NXD Mounting tabs to accommodate the installation of the
drywall or sheetrock after the rough-in box has been mounted. Ultimately, the Mounting Tabs
should lie flush against the outside of the sheetrock.
2.
Fasten the CB-TP5 rough-in box to the stud through the holes on the right Stud Mounting tabs (FIG. 16),
using either nails or screws.
3.
Remove the wiring knockouts from the left side of the rough-in box (CB-TP5) (FIG. 16) to accommodate
the cables being threaded through to the NXD touch panel.
4.
Thread the incoming power, RJ-45 audio/video, Ethernet, and USB wiring through the knockouts (use of
the left wiring knockouts are recommended with this installation).
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
5.
Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP5.
FIG. 16
CB-TP5 rough-in box components
Stud
Stud Mounting tabs
Drywall or sheetrock
Wiring
knockouts (6)
(must be
located on
left side)
NXD Mounting tabs
(should lie flush against
the outside of the wall)
Remember that when mounting this rough-in box, the NXD mounting tabs must lie
flush against the outside of the sheetrock.