Installation of an nxd touch panel, Installing the nxd panel within a rough-in box – AMX Modero NXD-CV5 User Manual
Page 30
Installation
18
NXD-CV5 5" Modero Wall/Flush Mount Touch Panel
Installation of an NXD Touch Panel
The NXD-CV5 can be installed either directly into the (optional) CB-TP5 or other solid surface environment
using the two different mounting options: drywall clips or solid surface screws. The following sections
describe mounting the touch panel directly into a pre-wall rough-in box, a solid surface or drywall, and
optional NXA-RK5 Rack Mount Kit.
Installing the NXD panel within a Rough-In Box
The rough-in box must be mounted prior to continuing this section. Refer to the procedures in the
Pre-Wall Installation of the Rough-In Box section on page 16 for detailed pre-wall installation instructions.
Verify that all necessary cables have been threaded through the knockouts on the left of the rough-in box and
the connections have been tested prior to installation of the NXD-CV5.
1.
Remove the Faceplate/bezel (A in FIG. 17) from the main NXD unit (B in FIG. 17) by gripping the
faceplate and pulling with gentle outward force.
2.
Verify the incoming power, RJ-45 audio/video, Ethernet, and USB cables have been properly threaded
through the wiring knockouts on the left of the rough-in box. Leave enough slack in the wiring to
accommodate any re-positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding locations along the side of the (un-
powered) NXD touch panel.
Verify that the terminal end of the power cable is not connected to a power source before plugging
in the 2-pin power connector.
The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.
4.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify that the panel is receiving power and functioning properly to prevent repetition of the
installation.
5.
Disconnect the terminal end of the power cable from the connected power supply.
FIG. 17
NXD-CV5 panel installation into a CB-TP5 (pre-wall construction)
B - Main NXD unit consists of
C - Optional CB-TP5
#4-40 Mounting Screws
(three - included)
secure the NXD to
Stud
the touch panel and back box housing
rough-in/wallbox
A - Faceplate/Trim Ring
default Faceplate comes with buttons
the Rough-In Box
Mounting Tab
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the rough-in box.