P201 nominal motor frequency, P202 nominal speed, P203 nominal current – NORD Drivesystems BU0500 User Manual
Page 82
SK 500E – Users Manual for Frequency Inverters
82
BU 0500 GB-1013
2 = 0.25kW 230V
3 = 0.33 Hp 230V
4 = 0.25kW 400V
5 = 0.33 Hp 460V
6 = 0.37kW 230V
7 = 0.50 Hp 230V
8 = 0.37kW 400V
9 = 0.50 Hp 460V
10 = 0.55kW 230V
11 = 0.75 Hp 230V
12 = 0.55kW 400V
13 = 0.75 Hp 460V
14 = 0.75 Hp 230V
15 = 1.0 Hp 230V
16 = 0.75 Hp 400V
17 = 1.0 Hp 460V
18 = 1.1 kW 230V
19 = 1.5 Hp 230V
20 = 1.1 kW 400V
21 = 1.5 Hp 460V
22 = 1.5 Hp 230V
23 = 2.0 Hp 230V
24 = 1.5 Hp 400V
25 = 2.0 Hp 460V
26 = 2.2 kW 230V
27 = 3.0 Hp 230V
28 = 2.2 kW 400V
29 = 3.0 Hp 460V
30 = 3.0 Hp 230V
31 = 3.0 Hp 400V
32 = 4.0 kW 230V
33 = 5.0 PS 230V
34 = 4.0 kW 400V
35 = 5.0 PS 460V
36 = 5.5 kW 230V
37 = 7.5 PS 230V
38 = 5.5 kW 400V
39 = 7.5 PS 460V
40 = 7.5 kW 230V
41 = 10.0 PS 230V
42 = 7.5 kW 400V
43 = 10.0 PS 460V
44 = 11.0 kW 400V
45 = 15.0 PS 460V
46 = 15.0 kW 400V
47 = 20.0 PS 460V
48 = 18.5 kW 400V
49 = 25.0 PS 460V
50 = 22.0 kW 400V
51 = 30.0 PS 460V
52 = 30.0 kW 400V
53 = 40.0 PS 460V
54 = 37.0 kW 400V
55 = 50.0 PS 460V
56 = 45.0 kW 400V
57 = 60.0 PS 460V
58 = 55.0 kW 400V
59 = 75.0 PS 460V
60 = 75.0 kW 400V
61 = 100.0 PS 460V
62 = 90.0 kW 400V
63 = 120.0 PS 460V
64 = 110.0 kW 400V
65 = 150.0 PS 460V
66 = 132.0 kW 400V
67 = 180.0 PS 460V
68 = 160.0 kW 400V
69 = 220.0 PS 460V
70 = 200.0 kW 400V
71 = 270.0 PS 460V
72 = 250.0 kW 400V
73 = 340.0 PS 460V
NOTE:
As P200 returns to = 0 after the input confirmation, the control of the set motor can be implemented
via parameter P205.
Information
IE2 motors
For the use of IE2 motors, after the selection of an IE1 motor (P200) the motor data in P201 ...
P209 must be adapted to the data on the motor type plate.
Pos : 121 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P201 – M ot or N ennfr equenz @ 0\ mod_1327588385923_388. doc x @ 7884 @ @ 1
P201
Nominal motor frequency
(Nominal motor frequency)
S
P
10.0 ... 399.9 Hz
The motor nominal frequency determines the V/f break point at which the FI supplies the nominal
P202
Nominal speed
(Nominal motor speed)
S
P
150 ... 24000 rpm
{
***
}
The nominal motor speed is important for the correct calculation and control of the motor slip and
the speed display (P001 = 1).
Pos : 123 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P203 – M ot or N ennstr om @ 0\ mod_1327588500455_388.doc x @ 7930 @ @ 1
P203
Nominal current
(Nominal motor current)
S
P
0.1 ... 1000.0 A
{
***
}
The nominal motor current is a decisive parameter for the current vector control.
*** These settings are dependent on the nominal power of the FI or the selection in parameter P200.