2 assembly and installation – NORD Drivesystems BU0500 User Manual
Page 35
2 Assembly and installation
BU 0500 GB-1013
35
Inverter ID
NORD
SK 500E
Input choke 3 x 380 - 480 V
L1
W1
D
Detail: Mounting
C
o
n
n
e
c
ti
o
n
Type
Continuous
current
Inductance
L2
B2
Ins
ta
ll
a
tion
0.55 ... 2.2 kW
SK CI1-480/6-C
Part. No.: 276993006
6 A
3 x 4.88 mH
96
60
117
71
45
M4
4
3.0 ... 4.0 kW
SK CI1-480/11-C
Part. No.: 276993011
11 A
3 x 2.93 mH 120
85
140
105
70
M4
4
5.5 ... 7.5 kW
SK CI1-480/20-C
Part. No.: 276993020
20 A
3 x 1.47 mH 155
110
177
135
95
M5
10
11 ... 15 kW
SK CI1-480/40-C
Part. No.: 276993040
40 A
3 x 0.73 mH 155
115
172
135
95
M5
10
18 ... 30hp
SK CI1-480/70-C
Part. No.: 276993070
70 A
3 x 0.47 mH 185
122
220
170
77
M6
35
37 … 45 kW SK CI1-480/100-C
Part. No.: 276993100
100 A
3 x 0.29 mH 240
148
263
180
122
M6
35
55 … 75 kW SK CI1-480/160-C
Part. No.: 276993160
160 A
3 x 0.18 mH 352
140
268
240
105
M8
M8*
90 kW SK CI1-480/280-C
Part. No.: 276993280
280 A
3 x 0.10 mH 352
169
268
240
133 M10 M16*
All dimensions in [mm]
[mm
2
]
* Bolt for copper rail
Table 11: Mains choke data for SK CI1-..., 3~ 480 V
Pos : 41 /Anl eitungen/ Elektroni k/FU und Start er/ 2. M ont age und Ins tall ati on/ 2. 8 Ausgangsdr ossel SK C O1 [BU 0500, u.A.] @ 0\ mod_1325863040983_388. doc x @ 5963 @ 2 @ 1