2 assembly and installation – NORD Drivesystems BU0500 User Manual
Page 55
2 Assembly and installation
BU 0500 GB-1013
55
Terminal block X8 – Safe pulse lock (not with 115V devices)
Relevance
SK 500E
SK 505E
SK 510E
SK 511E
SK 515E
SK 520E
SK 530E
SK 535E
√
√
√
Terminal X8:
86
87
88
89
VO_S 15V
VO_S 0V
VI_S 0V
VI_S 24V
Name
Terminal Function
[factory setting]
Data
Description / wiring suggestion
Parameter
86
Supply voltage
Details: BU0530!
When setting-up without using a safety
function, wire directly to V_IS 24V.
P420 et seq.
87
Reference potential
88
Reference potential
Details: BU0530!
Fail-safe input
89
Input
'safe pulse block'
Relevance
SK 500E
SK 505E
SK 510E
SK 511E
SK 515E
SK 520E
SK 530E
SK 535E
√
√
Terminal X8:
86
87
88
89
VO_S 24V
VO_S 0V
VI_S 0V
VI_S 24V
Name
Terminal Function
[factory setting]
Data
Description / wiring suggestion
Parameter
86
Supply voltage
Details: BU0530!
When setting-up without using a safety
function, wire directly to V_IS 24V.
P420 et seq.
87
Reference potential
88
Reference potential
Details: BU0530!
Fail-safe input
89
Input
'safe pulse block'