beautypg.com

P545 actual bus value 3, P546 digital bus setpoint 1, P547 digital bus setpoint 2 – NORD Drivesystems BU0500 User Manual

Page 126: P548 digital bus setpoint 3

background image

SK 500E – Users Manual for Frequency Inverters

126

BU 0500 GB-1013

P545

Actual bus value 3

(Actual bus value 3)

S

P

0 ... 24

{ 0 }

This parameter is identical to P543.

Condition is PPO 2 or PPO 4 type (P507).

Pos : 307 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P546 – Funkti on Bus-Soll wert 1 [ SK 500... 535E] @ 0\ mod_1328097962990_388. doc x @ 11916 @ @ 1

P546

Digital Bus setpoint 1

(Function of bus setpoint 1)

S

P

0 ... 55

{ 1 }

In this parameter, a function is allocated to the output setpoint 1 during bus actuation.

The possible analog functions can be found in the following table.

NOTE:

For further details please refer to the manual for the frequency inverter (P400, P546),

the relevant BUS operating instructions or the manuals BU 0510 / BU0550.

Pos : 309 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P546 – Funkti on Bus-Soll wert e, Ei nst ellungen [ SK 5xxE] @ 2\ mod_1354267859195_388.doc x @ 51897 @ @ 1

0 =

Off

16 = Process controller lead

1 =

Setpoint frequency

17 = BusIO In Bits 0...7

2 =

Torque current limit (P112)

18 = Curve travel calculator

3 =

Actual frequency PID

19 = Set relays, "Output status"

(P434/441/450/455=38)

4 =

Frequency addition

20 = Set analog output (P418=31)

5 =

Frequency subtraction

21 = ... 45 reserved from SK 530E and above

à

BU 0510

6 =

Current limit (P536)

46 = Setpoint Torque processreg., "Setpoint

torque process controller"

7 =

Maximum frequency (P105)

47 = reserved from SK 530E and above

à

BU 0510

8 =

Actual PID frequency limited

48 = Motor temperature (SK 540E and above)

9 =

Actual PID frequency monitored

49 = reserved from SK 540E and above

à

BU 0510

10 = Torque servo mode (P300)

53 = d-correction F process (SK 540E and

above)

11 = Torque precontrol (P214)

54 = d-correction Torque (SK 540E and above)

12 = Reserved

55 = d-correction F+torque (SK 540E and

above)

13 = Multiplication

56 = reserved from SK 540E and above

à

BU 0510

14 = Process controller actual value

57 = reserved from SK 540E and above

à

BU 0510

15 = Process controller setpoint

Scaling details: See Section 8.8

Pos : 310 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P547 – Funkti on Bus-Soll wert 2 [ SK 500... 535E] @ 0\ mod_1328098180008_388. doc x @ 11962 @ @ 1

P547

Digital Bus setpoint 2

(Function of bus setpoint 2)

S

P

0 ... 55

{ 0 }

This parameter is identical to P546.

Pos : 311 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P548 – Funkti on Bus-Soll wert 3 [ SK 500... 535E] @ 0\ mod_1328098278323_388. doc x @ 11985 @ @ 1

P548

Digital Bus setpoint 3

(Function of bus setpoint 3)

S

P

0 ... 55

{ 0 }

This parameter is identical to P546.

Pos : 312 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P549 – Funkti on Poti-Box @ 0\ mod_1328098389279_388. doc x @ 12008 @ @ 1