Functions of the SimpleBox
7-segment LED
display
When the frequency inverter is ready for operation any initial value (P104/P113 for keyboard
operation) is indicated by a flashing display. This frequency is immediately used on being
enabled.
During operation, the currently set operating value (selection in P001) or an error code (Section 6)
is displayed.
During parameterisation, the parameter numbers or the parameter values are shown.
LEDs
1
2
The LEDs indicate the actual operating parameter set in the operating display (P000) and
the current parameter set being parameterised. The display is in binary code.
1
2
= P1
2
1
= P2
1
2
= P3
2
1
= P4
Turn the knob to
the right
Turn the knob to the right in order to increase the parameter number or the parameter
value.
Turn the knob to
the left
Turn the knob to the left in order to reduce the parameter number or the parameter value.
Briefly press the
knob
Briefly pressing the knob = “ENTER” function in order to store a changed parameter or to
change from parameter number to parameter value.
Press the knob
for longer
If the knob is pressed for a longer period, the display changes to the next higher level, if
necessary without storing a parameter change.
Table 27: SimpleBox SK CSX-0, functions
Control with the SimpleBox
If P549=1 is set and the operating value display P000 is selected, the drive can be controlled with the
SimpleBox on the FI.
Depressing the button for a long time starts the drive, pressing briefly stops it. The speed of rotation
can be controlled in the positive and negative range by means of the rotating knob.
Note
Stopping the drive
In this operating mode, the drive can only be stopped with the button in the operating value display (short press)
or by switching off the mains voltage.