NORD Drivesystems BU0500 User Manual
Page 107
5 Parameters
BU 0500 GB-1013
107
P442
Relay 2 scaling
(Scaling of output 2 (Relay 2 – MFR1))
P
-400 ... 400 %
{ 100 }
Functions are identical to P435!
Pos : 238 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P443 – H yst eres e Ausgang 2 (R elais 2 - MFR2) [SK 500. .. 535E] @ 1\ mod_1332166000193_388.doc x @ 19191 @ @ 1
P443
Relay 2 hysteresis
(Hysteresis of output 2 (Relay 2 – MFR1))
S
P
1 ... 100 %
{ 10 }
Functions are identical to P436!
Pos : 239 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P450 – Funkti on Ausgang 3 (DOUT 1) [ SK 500.. .535E] @ 0\ mod_1328001789025_388. doc x @ 10434 @ @ 1
P450
Relay 3 function
(Function of output 3 (DOUT1))
SK 520E or
higher
P
0 ... 39
{ 0 }
Control terminals 5/40: Functions are identical to P434! Digital output, 15V against DGND (for
SK 5x5E devices, deviations of the signal level are ).
Pos : 240 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P451 – N or mier ung Ausgang 3 (D OUT1) [SK 500... 535E] @ 0\ mod_1328001846682_388. doc x @ 10457 @ @ 1
P451
Relay 3 scaling
(Scaling of output 3 (DOUT1))
SK 520E or
higher
P
-400 ... 400 %
{ 100 }
Functions are identical to P435!
Pos : 241 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P452 – H yst eres e Ausgang 3 (D OUT1) [SK 500. .. 535E] @ 0\ mod_1328001900416_388. doc x @ 10480 @ @ 1
P452
Relay 3 Hyst.
(Output 3 hysteresis (DOUT1))
SK 520E or
higher
S
P
1 ... 100 %
{ 10 }
Functions are identical to P436!
Pos : 242 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P455 – Funkti on Ausgang 4 (DOUT 2) [ SK 500.. .535E] @ 0\ mod_1328001962995_388. doc x @ 10503 @ @ 1
P455
Relay 4 function
(Function of output 4 (DOUT2))
SK 520E or
higher
P
0 ... 39
{ 0 }
Control terminals 7/40: Functions are identical to P434! Digital output, 15V against DGND (for
SK 5x5E devices, deviations of the signal level are possible).
Pos : 243 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P456 – N or mier ung Ausgang 4 (D OUT2) [SK 500... 535E] @ 0\ mod_1328002026792_388. doc x @ 10526 @ @ 1
P456
Relay 4 scaling
(Scaling of output 4 (DOUT2))
SK 520E or
higher
P
-400 ... 400 %
{ 100 }
Functions are identical to P435!
Pos : 244 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P400-P499/ Paramet er P457 – H yst eres e Ausgang 4 (D OUT2) [SK 500. .. 535E] @ 0\ mod_1328002078636_388. doc x @ 10549 @ @ 1
P457
Relay 4 Hyst.
(Output 4 hysteresis (DOUT2))
SK 520E or
higher
S
P
1 ... 100 %
{ 10 }
Functions are identical to P436!