Additional parameters, P501, Inverter name – NORD Drivesystems BU0500 User Manual
Page 112: P502, Value masterfunction
SK 500E – Users Manual for Frequency Inverters
112
BU 0500 GB-1013
Additional parameters
Parameter
{factory setting}
Setting value / Description / Note
Supervisor
Parameter set
Pos : 260 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P501 – U mric ht ername @ 0\ mod_1328091645446_388. doc x @ 10904 @ @ 1
P501
[-01]
...
[-20]
Inverter name
(Inverter name)
A…Z
(char)
{ 0 }
Free input of a designation (name) for the device (max. 20 characters). With this, the frequency
inverter can be uniquely identified for setting with NORD CON software or within a network.
Pos : 261 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P502 – Wert Leitf unktion @ 0\ mod_1328091690836_388. doc x @ 10927 @ @ 1
P502
[-01]
...
[-05]
Value Masterfunction
(Value master function)
S
P
0 ... 57
{ all 0 }
Selection of the master value of a Master for output to a bus system (see P503) - (up to SK 535E:
max. 3 master values, SK 540 and above: max. 5 master values). The assignment of these
master values to the slave is carried out via (P546) (...(P548)):
[-01] = Master value 1
[-02] = Master value 2
[-03] = Master value 3
SK 540E and above:
[-04] = Master value 4
[-05] = Master value 5
Selection of possible setting values for master values:
00 = Off
01 = Actual frequency
02 = Actual speed
03 = Electricity
04 = Torque current
05 = State of digital inputs and
outputs
06 = Reserved
07 = Reserved
08 = Setpoint frequency
09 = Error message
10 = Reserved
11 = Reserved
12 = Digital Out Bit 0…7
13 = Reserved
14 = Reserved
15 = Reserved
16 = Reserved
17 = Value analog input 1
18 = Value analog input 2
19 = Setpoint frequency
master value
20 = Setpoint freq. after
master val ramp
21 = Actual freq. without
master value slip
22 = Speed encoder
23 = Actual freq. with slip
(SW V2.0 and above)
24 = Master value, act. freq.
with slip
(SW V2.0 and above)
53 = ... 57 Reserved
NOTE:
For details regarding the processing of setpoints and actual values, pleas refer to
Section 8.9.