beautypg.com

2 sk 5xxe…-cp in coldplate version, Sk 5xxe…-cp in coldplate version – NORD Drivesystems BU0500 User Manual

Page 24

background image

SK 500E – Users Manual for Frequency Inverters

24

BU 0500 GB-1013

2.2 SK 5xxE…-CP in ColdPlate version

Instead of a cooling element/fan, ColdPlate versions of the frequency inverter have a flat metal plate
on the rear side which is mounted on an existing mounting plate (e.g. the rear wall of the control
cabinet) so as to provide thermal conduction. A liquid cooling medium (water, oil) may also be passed
through the mounting surface. In this way, not only is the waste heat from the frequency inverter
dissipated more effectively, but also the waste heat from the inverter is prevented from remaining
inside the control cabinet. In addition to the optimisation of the power reserved and the service life of
the inverter, this also causes less thermal load on the inside of the control cabinet.

A further advantage of the ColdPlate version is the reduced installation depth of the device and the
fact that in general, there is no need for a fan on the frequency inverter.

Bottom-mounted brake resistors (SK BR4-…) cannot be mounted directly.

Frequency inverter type

Si

z

e

Envelope dimensions

[mm]

ColdPlate dimensions [mm]

Weight

Approx.

[kg]

A / H

B

C

h1

h2

u / k

Thickness

SK 5xxE-250- …-CP

SK 5xxE-750- …-CP

1

182

95

119

91

-

5.5

10

1.3

SK 5xxE-111- …-CP

SK 5xxE-221- …-CP

2

222

95

119

111

-

5.5

10

1.6

SK 5xxE-301- …-CP

SK 5xxE-401- …-CP

3

237

120

119

75.33

75.33

5.5

10

1.9

SK 5xxE-551- 340…-CP

SK 5xxE-751- 340…-CP

4

282

120

119

90.33

90.33

5.5

10

2.3

SK 5xxE-…CP

ColdPlate size 1 and size 2

ColdPlate size 3 and size4

Pos : 33 /Anl eitungen/ Elektroni k/FU und Start er/ 2. M ont age und Ins tall ati on/ 2. 3 D urc hst ec k-Ki t [ BU 0500] @ 0\ mod_1325861024826_388. doc x @ 5733 @ 2555 @ 1

A

C

B

Ø 4.5mm

k

u

h1

B

H

Ø 4.5mm

k

u

H

h1

h2

B