5 parameters, P740, Process data bus in – NORD Drivesystems BU0500 User Manual
Page 137: P741, Process data bus out, P742 data base version, P743 inverter type
5 Parameters
BU 0500 GB-1013
137
Pos : 369 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P740 – Prozes sdat en Bus In [ SK 500... 535E] @ 0\ mod_1328175248086_388. doc x @ 13313 @ @ 1
P740
[-01]
...
[-13]
Process Data Bus In
(Process data Bus In)
S
0000 ... FFFF (hex)
This parameter informs
about the actual control
word and the setpoints that
are transferred via the bus
systems.
For display, a BUS system
must be selected in P509
[-01 ] = Control word
Control word, source from
P509.
[-02] = setpoint value 1
[-03] = setpoint value 2
[-04] = setpoint value 3
Setpoint data from main
setpoint (P510 [-01]).
[-05] = Bus I/O In Bits (P480)
The displayed value depicts all
Bus In Bit sources linked with
"OR".
[-06] = Parameter data In 1
[-07] = Parameter data In 2
[-08] = Parameter data In 3
[-09] = Parameter data In 4
[-10] = Parameter data In 5
Data during parameter transfer:
Order label (AK),Parameter
number (PNU), Index (IND),
Parameter value (PWE 1/2)
[-11] = setpoint value 1
[-12] = setpoint value 2
[-13] = setpoint value 3
Setpoint data from the master
function value (Broadcast), if
P509 = 9/10
(P510 [-02])
Pos : 371 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P741 – Prozes sdat en Bus Out [ SK 500.. .535E] @ 0\mod_1328177890266_388. doc x @ 13359 @ @ 1
P741
[-01]
...
[-13]
Process Data Bus Out
(Process data Bus Out)
S
0000 ... FFFF (hex)
This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.
[-01] = Status word
Status word, source from
P509.
[-02] = Actual value 1 (P543)
[-03] = Actual value 2 (P544)
[-04] = Actual value 3 (P545)
[-05] = Bus I/O Out Bit (P481)
The displayed value depicts
all Bus OUT Bit sources linked
with "OR".
[-06 ] = Parameter data Out 1
[-07 ] = Parameter data Out 2
[-08 ] = Parameter data Out 3
[-09 ] = Parameter data Out 4
[-10 ] = Parameter data Out 5
Data during parameter
transfer.
[-11] = Actual value 1 master
function
[-12] = Actual value 2 master
function
[-13] = Actual value 3 master
function
Actual value of master
function
P502 / P503.
Pos : 373 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P742 – D at enbankversion @ 0\ mod_1328178021821_388.doc x @ 13405 @ @ 1
P742
Data base version
(Database version)
S
0 ... 9999
Displays the internal database version of the FI.
Pos : 374 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P743 – U mric ht ert yp @ 0\ mod_1328178080214_388.doc x @ 13428 @ @ 1
P743
Inverter type
(Inverter type)
0.00 ... 250.00
Displays the inverter power in kW, e.g. "1.50"
Þ FI with 1.5 kW nominal power.