4 limitations of saving, 5 saving data, 5 saving data settings – KYORITSU 6310 Instruction Manual User Manual
Page 229: Save data
![background image](/manuals/369632/229/background.png)
KEW6310 11.4.4 Power quality –Limitations of saving (Inrush current measurement)
KEW6310
11.24
11.4.4 Limitations of saving
Refer to “6.3.2 Limitations of saving” in this manual.
11.4.5 Saving data
Settings
FILE ID
: File name
VERSION :
Version
info
ID NUMBER
: ID number
SENSOR TYPE
: Model name of Clamp sensor
CURRENT RANGE
: Current Range
CURRENT FILTER
: Current Filter
FREQUENCY :
Frequency
REFERENCE CURRENT
: Reference current
INRUSH CURRENT
: Threshold for Inrush current
HYSTERESIS :
Hysteresis
TRIGGER POINT
: Trigger point
START
: Saving start time
Save data
File ID : 6310-09
Saved time & date
Start / End
Duration
Max / Min
Data
DATE TIME
I/O
DURATION MAX/MIN
201
data
pts
yyyy/mm/dd h:mm:ss
1
0
1 / 0
--:--:--.--
h:mm:ss.ss
(±)x.xxxxE±nn
Year/Month/Day Hour:Min:sec
START
END
START to
END
Start
End
Max / Min
(±) value x 10
±n
File ID : 6310-015*
Saved time & date
Elapsed time
Instantaneous
Average
Max
Min
DATE TIME
ELAPSED
TIME
INST
AVG
MAX
MIN
yyyy/mm/dd h:mm:ss h:mm:ss
(±)x.
xxxE±nn
Year/Month/Date Hour:Min:Sec
Hour:Min:Sec
(±) value x 10
±n
* File ID: 6310-15 is used when saving data on ver2.00 or later.