6

OPERATION

90

OPTISONIC 6300

www.krohne.com

07/2009 - 4000263902 - HB OPTISONIC 6300 R03 en

C5.4.11

phase shift

phase shift between output B and

D

0, 90, 180 degrees

C5.4.12

special function

for ranging

off, phase shift

C5.4.13

information

serial number of circuit board,

software version, calibration date

of circuit board

C5.4.14

simulation

simulation of pulse output

on, off, cancel

C5.5

C5.5

C5.5

C5.5

status output

status output

status output

status output

C5.5.1

mode

output is activated if an error

occurs

(depends on pipe configuration: 1 or 2 pipes)

off, error in device, application error, out of

specification, empty pipe, polarity flow, over

range flow, application error 1 or 2, out of

specification 1 or 2, empty pipe 1 or 2, polarity

flow 1 or 2, over range flow 1 or 2, counter 1

preset, counter 2 preset, output A/B/C/D

C5.5.2

current output Y

active if selected under status

output mode (C2.5.1) output Y and

output is current output

polarity, over range, automatic range

C5.5.3

frequency output Y

active if selected under status

output mode (C2.5.1) output Y and

output is frequency output

polarity, over range

C5.5.4

pulse output D

active if selected under status

output mode (C2.5.1) output Y and

output is pulse output

polarity, over range

C5.5.5

status output Y

active if selected under status

output mode (C2.5.1) output Y and

output is status output

same signal, inverted signal

C5.5.6

limit switch Y

active if selected under status

output mode (C2.5.1) output Y and

output is limit switch

off

C5.5.7

control input Y

active if selected under status

output mode (C2.5.1) output Y and

output is control input

off

C5.5.8

off

active if selected under status

output mode (C2.5.1) output Y and

output is switched off

off

C5.5.9

invert signal

define status output activation

off: activate high current/switch closed

on: low current/switch open

C5.5.10

information

serial number of circuit board,

software version, calibration date

of circuit board

C5.5.11

simulation

simulation of status output

on, off, cancel

C5.6

C5.6

C5.6

C5.6

limit switch X

limit switch X

limit switch X

limit switch X

C5.6.1

measurement

measurement value to limit

switch

(depends on pipe configuration: 1 or 2 pipes)

volume flow, mass flow, VoS, flow speed, gain,

SNR, diagnosis value, volume flow 1 or 2, VoS 1

or 2

C5.6.2

threshold

1e: switch level 2e:time lag

min-max: 500.0 - 2500 m/s

C5.6.3

polarity

set polarity of limit switch

positive -, negative -, both polarity(ies), absolute

value

C5.6.4

time constant

within set time, measurements

are averaged, displayed and sent

to current output

min-max: 000.1 - 100.0

C5.6.5

invert signal

define limit switch activation

off: high current by exceeded limit

on: low current by exceeded limit

C5.6.6

information

serial number of circuit board,

software version, calibration date

of circuit board

.book Page 90 Tuesday, August 18, 2009 4:51 PM