Control input
Control input
Control input
Control input
Function
Hold value of the outputs (e.g. for cleaning work), set value of the
outputs to "zero", counter and error reset, range change.
Start of dosing when dosing function is activated.
Operating data
Basic I/Os
Basic I/Os
Basic I/Os
Basic I/Os
Modular I/Os
Modular I/Os
Modular I/Os
Modular I/Os
Ex-i
Ex-i
Ex-i
Ex-i
Active
-
U
int
= 24 VDC
Terminals open:
U
0, nom
= 22 V
Terminals bridged:
I
nom
= 4 mA
On:
U
0
≥ 12 V with
I
nom
= 1.9 mA
Off:
U
0
≤ 10 V with
I
nom
= 1.9 mA
-
Passive
8 V ≤ U
ext
≤ 32 VDC
I
max
= 6.5 mA
at U
ext
≤ 24 VDC
I
max
= 8.2 mA
at U
ext
≤ 32 VDC
Contact closed (On):
U
0
≥ 8 V
with I
nom
= 2.8 mA
Contact open (Off):
U
0
≤ 2.5 V
with I
nom
= 0.4 mA
3 V ≤ U
ext
≤ 32 VDC
I
max
= 9.5 mA at
U
ext
≤ 24 V
I
max
= 9.5 mA at
U
ext
≤ 32 V
Contact closed (On):
U
0
≥ 3 V
with I
nom
= 1.9 mA
Contact open (Off):
U
0
≤ 2.5 V
with I
nom
= 1.9 mA
U
ext
≤ 32 VDC
I ≤ 6 mA at U
ext
= 24 V
I ≤ 6.6 mA at
U
ext
= 32 V
On:
U
0
≥ 5.5 V or I ≥ 4 mA
Off:
U
0
≤ 3.5 V or
I ≤ 0.5 mA
U
I
= 30 V
I
I
= 100 mA
P
I
= 1 W
C
I
= 10 nF
L
I
= 0 mH
NAMUR
-
Active to EN 60947-5-
6
Contact open:
U
0, nom
= 8.7 V
Contact closed (On):
I
nom
= 7.8 mA
Contact open (off):
U
0, nom
= 6.3 V with
I
nom
= 1.9 mA
Identification for
open terminals:
U
0
≥ 8.1 V with
I ≤ 0.1 mA
Identification for
short circuited
terminals:
U
0
≤ 1.2 V with
I ≥ 6.7 mA
-
Low-flow cutoff
Low-flow cutoff
Low-flow cutoff
Low-flow cutoff
On
0...±9.999 m/s; 0...20.0%, settable in 0.1% steps, separately for each
current and pulse output
Off
0...±9.999 m/s; 0...19.0%, settable in 0.1% steps, separately for each
current and pulse output
Time constant
Time constant
Time constant
Time constant
Function
Can be set together for all flow indicators and outputs, or separately
for: current, pulse and frequency output, and for limit switches and
the 3 internal counters
Time setting
0…100 seconds, settable in 0.1 second steps
.book Page 113 Tuesday, August 18, 2009 4:51 PM