OPERATION
86
OPTISONIC 6300
www.krohne.com
07/2009 - 4000263902 - HB OPTISONIC 6300 R03 en
6.3 Function description
Menu No.
Display
Function description
Selection list
X
XX
X
Installation
Installation
Installation
Installation
X3
X3
X3
X3
units
units
units
units
X3.1
size
unit for dimension
mm, inch
X3.2
volume flow
unit for volume flow
L/s, L/min,L/h, m3/s, m3/min, m3/h, m3/d,
ft3/s, ft3/min, ft3/h, gal/s, gal/min,gal/h, gal/d,
IG/s, IG/min, IG/h, IG/d, bbl/h, bbl/d, free unit
X3.3
velocity
unit for flow speed and velocity of
sound (VoS)
m/s, ft/s
X3.4
density
unit for density
kg/L, kg/m3, lb/ft3, lb/gal, free unit
X3.5
viscosity
unit for viscosity
cSt, mm2/s
X5
X5
X5
X5
number of paths
number of paths
number of paths
number of paths
in case "2 paths" is selected, the
measurement results will be
averaged
1 path, 2 paths
X6.3
diameter
size for outer diameter of pipe
min-max: 20 - 4300 mm / 0.787 - 169.3 inch
X6.4
pipe material
carbon steel, stainless steel, cast iron,
aluminum, concrete, GRF/RFP, asbestos
cement, PP/PVC, acrylics, polyamide, other
X6.5
VoS pipe material
min-max: 1000.0 - 4500.0 m/s / 3280.8 - 14764
ft/s
X6.6
wall thickness
min-max: 1.000 - 200.0 mm / 0.039 - 7.874 inch
X6.7
liner material
cement, epoxy, PP, LDPE, HDPE, PTFE, rubber,
other, none
X6.8
VoS liner material
min-max: 1000.0 - 4500.0 m/s / 3280.8 - 14764
ft/s
X6.9
liner thickness
min-max: 0.100 - 20.00 mm / 0.004 - 0.787 inch
X6.10
fluid
water, alkanes, alcohols, oil, acids, CxHx
refined, CxHx light, refrigerant, solvents,
caustic soda, other
X6.11
VoS fluid
min-max: 500 - 2500 m/s / 1640.4 - 8202.1 ft/s
X6.12
density
min-max: 0.1000 - 5.0000 kg/l / 6.2428 lb/ft3 to
312.14 lb/ft3
X6.13
viscosity
min-max: 0.100 cSt to 9999 cSt (mm2/s)
X9.1
transducer set
short code for transducer set,
mentioned on sensor
Ta, Tb, Tc, none
X9.7
actual distance
min-max: -10.00 - +9999 mm / -0.394 - +393.7
inch
X12.1/3/5
Tx serial no.
factory serial number of sensor
Ayy, 5 free units
X12.2/4/6
Tx calibration no.
set calibration number of sensor
according to type sticker
9 free units
A Quick setup
A
A
A
A
quick setup
quick setup
quick setup
quick setup
A1
A1
A1
A1
language
language
language
language
english, german, french, dutch
A2
A2
A2
A2
Tag
Tag
Tag
Tag
unique location in plant
12 free selectable digits
A4
A4
A4
A4
analog outputs
analog outputs
analog outputs
analog outputs
only active if HART device
current output A, B or C, pulse output A, B or D
A4.1
measurement
value for HART current output
(depends on pipe configuration: 1 or 2 pipes)
volume flow, mass flow, VoS, flow speed, gain,
SNR, diagnosis value, volume flow 1 or 2, VoS 1
or 2
.book Page 86 Tuesday, August 18, 2009 4:51 PM