Technical data – KROHNE OPTISONIC 6300 EN User Manual
Page 110
8
TECHNICAL DATA
110
OPTISONIC 6300
www.krohne.com
07/2009 - 4000263902 - HB OPTISONIC 6300 R03 en
Inputs and outputs
General
All in- and outputs are galvanically isolated from each other and from
all other circuits
Description of used abbreviations U
ext
= external voltage; R
L
= load + resistance; U
o
= terminal voltage;
I
nom
= nominal current
Current output
Current output
Current output
Current output
Output data
Measurement of volume and mass (at constant density), HART
®
communication
Settings
Without HART
Without HART
Without HART
Without HART
®
Q = 0%: 0…20 mA; Q = 100%: 10…21.5 mA
Error identification: 0…22 mA
With HART
With HART
With HART
With HART
®
Q = 0%: 4…20 mA; Q = 100%: 10…21.5 mA
Error identification: 3.5…22 mA
Operating data
Basic I/Os
Basic I/Os
Basic I/Os
Basic I/Os
Modular I/Os
Modular I/Os
Modular I/Os
Modular I/Os
Ex-i
Ex-i
Ex-i
Ex-i
Active
U
int,nom
= 24 VDC
I ≤ 22 mA
R
L
≤ 1 kΩ
U
int,nom
= 20 VDC
I ≤ 22 mA
R
L
≤ 450 Ω
U
0
= 21 V
I
0
= 90 mA
P
0
= 0.5W
C
0
= 90 nF /
L
0
= 2 mH
C
0
= 110 nF /
L
0
= 0.5 mH
Passive
U
ext
≤ 32 VDC
I ≤ 22 mA
U
0
≥ 1.8 V at I = 22 mA
U
ext
≤ 32 VDC
I ≤ 22 mA
U
0
≥ 4 V
R
L
≤(U
ext
- U
o
) / I
max
U
I
= 30 V
I
I
= 100 mA
P
I
= 1 W
C
I
= 10 nF
L
I
~ 0 mH
HART
HART
HART
HART
®
Description
HART
®
protocol at active and passive current output
HART
®
version: V5
Universal HART
®
parameter fully integrated
Load
≥ 250 Ω
Please observe maximum value for current output
Multidrop
Yes, current output = 4 mA
Multidrop addresses programmable in menu 1...15
Device drivers
FDT/DTM
.book Page 110 Tuesday, August 18, 2009 4:51 PM