beautypg.com

Electrical connections – KROHNE OPTISONIC 6300 EN User Manual

Page 40

background image

4

ELECTRICAL CONNECTIONS

40

OPTISONIC 6300

www.krohne.com

07/2009 - 4000263902 - HB OPTISONIC 6300 R03 en

4.5.2 Basic inputs/outputs

Current output active (HART

®

), basic I/Os

• U

int,nom

= 24 VDC nominal

• I ≤ 22 mA
• R

L

≤ 1 kΩ

Current output passive (HART

®

), basic I/Os

• U

int,nom

= 24 VDC nominal

• U

ext

≤ 32 VDC

• I ≤ 22 mA
• U

0

≥ 1.8

• R

L

≤ (U

ext

- U

0

) / I

max

CAUTION!
Observe connection polarity.

Figure 4-11: Current output active I

a

Figure 4-12: Current output passive I

p