Electrical connections – KROHNE OPTISONIC 6300 EN User Manual
Page 45
ELECTRICAL CONNECTIONS
4
45
OPTISONIC 6300
www.krohne.com
07/2009 - 4000263902 - HB OPTISONIC 6300 R03 en
Description of abbreviations and CG identifier for possible optional modules
on terminals A and B
C _ _
max. 2 option modules for term. A + B
I
p
+ HART
®
passive
P
N
/ S
N
NAMUR
1
1 changeable
Abbreviation
Identifier for CG No.
Description
I
a
A
Active current output (including HART = HART
®
capability)
I
p
B
Passive current output (including HART = HART
®
capability)
P
a
/ S
a
C
Active pulse, frequency, status output or limit switch (changeable)
P
p
/ S
p
E
Passive pulse, frequency, status output or limit switch (changeable)
P
N
/ S
N
F
Passive pulse, frequency, status output or limit switch according to
NAMUR (changeable)
C
a
G
Active control input
C
p
K
Passive control input
C
N
H
Active control input to NAMUR
Signal converter monitors cable breaks and short circuits as per EN
60947-5-6. Errors indicated on LCD display. Error messages possible via
status output.
IIn
a
P
Active current input
IIn
p
R
Passive current input
-
8
No additional module installed
-
0
No further module possible
CG-No. Connection terminals
A+
A
A-
B
B-
C
C-
D
D-
.book Page 45 Tuesday, August 18, 2009 4:51 PM