[G42: Alm Record Time1] Display the operation
time of alarm record1
This parameter is used to display the operation time
at which the alarm indicated by
G41: Alm Record1
was occurred. For example, “1D23:45” indicates
that an alarm was occured at the operation time of 1
day, 23 hours, and 45 minutes.
IMPORTANT
Use these values as a reference because the
time of alarm records (1 to 4) have an error.
[G43: Alm Record2] Alarm record2
This parameter is used to display the second most-
recent alarm, and the alarms that can be displayed
are the same as those for
G41: Alm Record1.
[G44: Alm Record Time2] Display the operation
time of alarm record2
This parameter is used to display the operation time
at which the alarm indicated by
G43: Alm Record2
was occurred. For example, “1D23:45” indicates
that an alarm was occured at the operation time of 1
day, 23 hours, and 45 minutes.
[G45: Alm Record3] Alarm record3
This parameter is used to display the third most-
recent alarm, and the alarms that can be displayed
are the same as those for
G41: Alm Record1.
[G46: Alm Record Time3] Display the operation
time of alarm record3
This parameter is used to display the operation time
at which the alarm indicated by
G45: Alm Record3
was occurred. For example, “1D23:45” indicates
that an alarm was occured at the operation time of 1
day, 23 hours, and 45 minutes.
[G47: Alm Record4] Alarm record4
This parameter is used to display the fourth most-
recent alarm, and the alarms that can be displayed
are the same as those for
G41: Alm Record1.
[G48: Alm Record Time4] Display the operation
time of alarm record4
This parameter is used to display the operation time
at which the alarm indicated by
G47: Alm Record4
was occurred. For example, “1D23:45” indicates
that an alarm was occured at the operation time of 1
day, 23 hours, and 45 minutes.
(7) Menu H: Display Setting items
Menu H contains setting items relevant to the
display unit.
[H10: Display Select1] Setting of the first line for
display unit
→
Refer to the description for parameter
B40
This parameter selects the display content of the
first line for display unit.
[H11: Display Select2] Setting of the second line
for display unit
→
Refer to the description for parameter
B41
This parameter selects the display content of the
second line for display unit.
[H12: Display Select3] Setting of the third line for
display unit
→
Refer to the description for parameter
B42
This parameter selects the display content of the
third line for display unit.
[H20: Display Cycle] Setting of the display cycle
This parameter sets the cycle for the display-
response speed of display unit. Settings should
be made in accordance with the measurement
environment by, for example, setting a longer
display cycle when using the equipment in low
temperatures.
[H30: Language] Selection of language used for
the display unit
→
Refer to the description for parameter
B10
This parameter can be used to select the language
for the display unit.
[H40: LCD Contrast] Selection of display contrast
This parameter is used to set the contrast of the
display (21 scales). Its contrast scale becomes
small (bright) when its parameter sets smaller.