Flange type – Yokogawa ADMAG AXR User Manual
Page 163
12-11
IM 01E30D01-01EN
<12. OUTLINE>
● Flange Type
Model
Suffix Code
Description
Applicable Model
AXR025
AXR040
AXR050
AXR065
AXR080
AXR100
AXR150
AXR200
----------------------------------------------
----------------------------------------------
----------------------------------------------
----------------------------------------------
----------------------------------------------
----------------------------------------------
----------------------------------------------
----------------------------------------------
Size 25 mm (1 in.)
Size 40 mm (1.5 in.)
Size 50 mm (2 in.)
Size 65 mm (2.5 in.)
Size 80 mm (3 in.)
Size 100 mm (4 in.)
Size 150 mm (6 in.)
Size 200 mm (8 in.)
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Use
G ---------------------------------------------
C ---------------------------------------------
General-Purpose Use
Explosion proof Type (*1)
Size 25 mm (1.0 in.) to
100 mm (4.0 in.)
Output Signal
and
Communication
-D --------------------------------
-E --------------------------------
-J --------------------------------
Integral Flowmeter with 4 to 20 mA DC Output and digital
communication (BRAIN protocol)
Integral Flowmeter with 4 to 20 mA DC Output and digital
communication (HART protocol) (*11)
Integral Flowmeter with 4 to 20 mA DC Output with digital
communication (HART5/HART7 protocol) (*12)
Power Supply
1 ------------------------------ Integral Flowmeter Operating voltage range 14.7 to 35 V DC
Two-wire system
Lining (*2)
A --------------------------- Fluorocarbon PFA
Electrode
Material (*2)
L ------------------------
P ------------------------
H ------------------------
T ------------------------
JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)
Platinum-iridium
Hastelloy C276 Equivalent
Tantalum
Electrode Structure
1 --------------------- Non-replaceable
Grounding Ring and
Grounding Electrode
Material (*2)
N ------------------
S ------------------
L ------------------
P ------------------
H ------------------
T ------------------
None (*3)
JIS SUS316 (AISI 316 SS/EN 1.4401 Equivalent)
JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)
Platinum-iridium
Hastelloy C276 Equivalent
Tantalum
Process Connection
(*4) (*5)
-BA1 -----------
-BA2 -----------
-BD1 -----------
-BD2 -----------
-BD4 -----------
-BJ1 -----------
-BJ2 -----------
-BG1 -----------
-CA1 -----------
-CA2 -----------
-CD1 -----------
-CD2 -----------
-CJ1 -----------
-CJ2 -----------
-CG1 ----------
ANSI Class 150
Flange JIS SUS304 or SUSF304
ANSI Class 300
Flange JIS SUS304 or SUSF304
DIN PN 10
Flange(JIS SUS304 or SUSF304) (*6)
DIN PN 16
Flange JIS SUS304 or SUSF304 (*6)
DIN PN 40
Flange JIS SUS304 or SUSF304 (*6)
JIS 10K
Flange JIS SUS304 or SUSF304
JIS 20K
Flange JIS SUS304 or SUSF304
JIS F12 (JIS75M)
Flange JIS SUS304 or SUSF304
ANSI Class 150
Flange (Carbon Steel)
ANSI Class 300
Flange (Carbon Steel)
DIN PN 10
Flange (Carbon Steel) (*6)
DIN PN 16
Flange (Carbon Steel) (*6)
JIS 10K
Flange (Carbon Steel)
JIS 20K
Flange (Carbon Steel)
JIS F12 (JIS75M)
Flange (Carbon Steel)
Size 200 mm (8.0 in.)
Size 65 mm (2.5 in.) to
100 mm (4.0 in.)
Size 25 mm (1.0 in.) to
50 mm (2.0 in.)
Size 80 mm (3.0 in.) to
100 mm (4.0 in.)
Size 150 mm (6.0 in.) to 200
mm (8.0 in.), Not available
for TIIS flameproof type.
Size 150 mm (6.0 in.) to 200
mm (8.0 in.), Not available
for TIIS flameproof type.
Size 200 mm (8.0 in.), Not
available for TIIS flame-
proof type.
Size 150 mm (6.0 in.) to 200
mm (8.0 in.), Not available
for TIIS flameproof type.
Size 150 mm (6.0 in.) to 200
mm (8.0 in.), Not available
for TIIS flameproof type.
Size 150 mm (6.0 in.) to 200
mm (8.0 in.), Not available
for TIIS flameproof type.
Size 150 mm (6.0 in.) to 200
mm (8.0 in.), Not available
for TIIS flameproof type.
Lay Length
1 ------------- Lay length code 1 (*7)
Electrical Connection (*8)
-0 ---------
-2 ---------
-4 ---------
JIS G1/2 female
ANSI 1/2 NPT female
ISO M20 × 1.5 female
Indicator (*9)(*10)
1 -------
2 -------
N -------
Integral Flowmeter with indicator (Horizontal)
Integral Flowmeter with indicator (Vertical)
Integral Flowmeter without indicator
Calibration
B ---- Always B
Options
/ Optional code (See the Table of Optional Specifications)