beautypg.com

Flange type – Yokogawa ADMAG AXR User Manual

Page 163

background image

12-11

IM 01E30D01-01EN

<12. OUTLINE>

● Flange Type

Model

Suffix Code

Description

Applicable Model

AXR025

AXR040

AXR050

AXR065

AXR080

AXR100

AXR150

AXR200

----------------------------------------------

----------------------------------------------

----------------------------------------------

----------------------------------------------

----------------------------------------------

----------------------------------------------

----------------------------------------------

----------------------------------------------

Size 25 mm (1 in.)

Size 40 mm (1.5 in.)

Size 50 mm (2 in.)

Size 65 mm (2.5 in.)

Size 80 mm (3 in.)

Size 100 mm (4 in.)

Size 150 mm (6 in.)

Size 200 mm (8 in.)

Two-wire Magnetic Flowmeter Integral Flowmeter

Two-wire Magnetic Flowmeter Integral Flowmeter

Two-wire Magnetic Flowmeter Integral Flowmeter

Two-wire Magnetic Flowmeter Integral Flowmeter

Two-wire Magnetic Flowmeter Integral Flowmeter

Two-wire Magnetic Flowmeter Integral Flowmeter

Two-wire Magnetic Flowmeter Integral Flowmeter

Two-wire Magnetic Flowmeter Integral Flowmeter

Use

G ---------------------------------------------

C ---------------------------------------------

General-Purpose Use

Explosion proof Type (*1)

Size 25 mm (1.0 in.) to

100 mm (4.0 in.)

Output Signal

and

Communication

-D --------------------------------

-E --------------------------------

-J --------------------------------

Integral Flowmeter with 4 to 20 mA DC Output and digital

communication (BRAIN protocol)

Integral Flowmeter with 4 to 20 mA DC Output and digital

communication (HART protocol) (*11)

Integral Flowmeter with 4 to 20 mA DC Output with digital

communication (HART5/HART7 protocol) (*12)

Power Supply

1 ------------------------------ Integral Flowmeter Operating voltage range 14.7 to 35 V DC

Two-wire system

Lining (*2)

A --------------------------- Fluorocarbon PFA

Electrode

Material (*2)

L ------------------------

P ------------------------

H ------------------------

T ------------------------

JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)

Platinum-iridium

Hastelloy C276 Equivalent

Tantalum

Electrode Structure

1 --------------------- Non-replaceable

Grounding Ring and

Grounding Electrode

Material (*2)

N ------------------

S ------------------

L ------------------

P ------------------

H ------------------

T ------------------

None (*3)

JIS SUS316 (AISI 316 SS/EN 1.4401 Equivalent)

JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)

Platinum-iridium

Hastelloy C276 Equivalent

Tantalum

Process Connection

(*4) (*5)

-BA1 -----------

-BA2 -----------

-BD1 -----------

-BD2 -----------

-BD4 -----------

-BJ1 -----------

-BJ2 -----------

-BG1 -----------

-CA1 -----------

-CA2 -----------

-CD1 -----------

-CD2 -----------

-CJ1 -----------

-CJ2 -----------

-CG1 ----------

ANSI Class 150

Flange JIS SUS304 or SUSF304

ANSI Class 300

Flange JIS SUS304 or SUSF304

DIN PN 10

Flange(JIS SUS304 or SUSF304) (*6)

DIN PN 16

Flange JIS SUS304 or SUSF304 (*6)

DIN PN 40

Flange JIS SUS304 or SUSF304 (*6)

JIS 10K

Flange JIS SUS304 or SUSF304

JIS 20K

Flange JIS SUS304 or SUSF304

JIS F12 (JIS75M)

Flange JIS SUS304 or SUSF304

ANSI Class 150

Flange (Carbon Steel)

ANSI Class 300

Flange (Carbon Steel)

DIN PN 10

Flange (Carbon Steel) (*6)

DIN PN 16

Flange (Carbon Steel) (*6)

JIS 10K

Flange (Carbon Steel)

JIS 20K

Flange (Carbon Steel)

JIS F12 (JIS75M)

Flange (Carbon Steel)

Size 200 mm (8.0 in.)

Size 65 mm (2.5 in.) to

100 mm (4.0 in.)

Size 25 mm (1.0 in.) to

50 mm (2.0 in.)

Size 80 mm (3.0 in.) to

100 mm (4.0 in.)

Size 150 mm (6.0 in.) to 200

mm (8.0 in.), Not available

for TIIS flameproof type.

Size 150 mm (6.0 in.) to 200

mm (8.0 in.), Not available

for TIIS flameproof type.

Size 200 mm (8.0 in.), Not

available for TIIS flame-

proof type.

Size 150 mm (6.0 in.) to 200

mm (8.0 in.), Not available

for TIIS flameproof type.

Size 150 mm (6.0 in.) to 200

mm (8.0 in.), Not available

for TIIS flameproof type.

Size 150 mm (6.0 in.) to 200

mm (8.0 in.), Not available

for TIIS flameproof type.

Size 150 mm (6.0 in.) to 200

mm (8.0 in.), Not available

for TIIS flameproof type.

Lay Length

1 ------------- Lay length code 1 (*7)

Electrical Connection (*8)

-0 ---------

-2 ---------

-4 ---------

JIS G1/2 female

ANSI 1/2 NPT female

ISO M20 × 1.5 female

Indicator (*9)(*10)

1 -------

2 -------

N -------

Integral Flowmeter with indicator (Horizontal)

Integral Flowmeter with indicator (Vertical)

Integral Flowmeter without indicator

Calibration

B ---- Always B

Options

/ Optional code (See the Table of Optional Specifications)