beautypg.com

Ped (pressure equipment directive), Ped (pressure equipment directive) -1, Warning – Yokogawa ADMAG AXR User Manual

Page 177

background image

<13. PED (PRESSURE EQUIPMENT DIRECTIVE)>

13-1

IM 01E30D01-01EN

This chapter describes further requirements and

notices concerning the PED (Pressure Equipment

Directive). The description in this chapter is prior to

other description in this User’s Manual.

(1) Technical Data

Module: H

Type of Equipment: Piping

Type of Fluid: Liquids and gas

Group of Fluid: 1 and 2

General-purpose Use/Explosion Proof Type:

MODEL

DN

(mm)

(*1)

PS

(MPa)

(*1)

PS · DN

(MPa ·

mm)

CATEGORY

(*2)

AXR025G/C

25

4

100

Article 3 (*3)

paragraph 3

AXR040G/C

40

4

160

II

AXR050G/C

50

4

200

II

AXR065G/C

65

2

130

II

AXR080G/C

80

2

160

II

AXR100G/C

100

2

200

II

AXR150G/C

150

2

300

II

AXR200G/C

200

2

400

III

*1:

PS: Maximum allowable pressure for Flowtube

DN: Nominal size

*2:

For details, see “Table 6 Covered by ANNEX II of EC

Directive on Pressure Equipment Directive 97/23/EC.”

*3:

AXR025G/C is outside the scope of CE marking for PED.

(2) Installation

WARNING

• Tighten the bolts of the piping joints

according to the prescribed torque values.

• Take measures to protect the flowmeters

from forces caused by vibration channeled

through the piping.

(3) Operation

WARNING

• The instrument should be operated with the

temperature and pressure of the fluid under

normal operating conditions.

• The ambient temperature should be that of

normal operating conditions.

• Take measures to prevent excessive

pressure such as water hammer, etc. To

avoid water hammer prevent the pressure

from exceeding the PS (maximum allowable

pressure) by setting the system’s safety

valves, etc. appropriately.

• Should external fire occur, take safety

measures at the device itself or system-wide

prevent it having an effect on the flowmeters.

• Avoid using fluids exceeding the corrosion

proof limitations of the lining and electrodes.

• Take measures not to abrade the metal pipe,

and avoid abrading the lining by using fluids

such as slurry and sand are contained.

13. PED (PRESSURE EQUIPMENT DIRECTIVE)