background image

Total Access 600 Series System Manual

Section 4 User Interface Guide

61200624L1-1B

© 2004 ADTRAN, Inc.

79

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

URRENT

AND

T

OTALS

> I

NTERVAL

Identifies the interval (

C

URRENT

or

T

OTAL

) for the listed performance statistics.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

URRENT

AND

T

OTALS

> ES

ES

(Errored Second) - For ESF mode, an errored second is defined as a second with one or more Path

Code Violations (PCVs), or one or more Out of Frame (OOF) defects, or one or more Controlled Slip
events, or a detected AIS (blue alarm) defect. For D4 (SF) mode, the presence of Bipolar Violations
(BPVs) also triggers an errored second.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

URRENT

AND

T

OTALS

> SES

SES

(Severely Errored Second) - For ESF mode, an

SES

is a second with 320 or more PCVs, or one or

more OOF defects, or a detected AIS defect. For D4 (SF) mode, an

SES

is a second with one or more

Framing Error events, or an OOF defect, or at least 1544 Line Code Violations or more.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

URRENT

AND

T

OTALS

> SEF

SEF

(Severely Errored Frame) - An

SEF

condition occurs when 2 out of 6 consecutive frame bits are in

error.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

URRENT

AND

T

OTALS

> FS

FS

(Frame Slip) - A frame slip is defined as one or more frame bit errors in a one-second interval.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

URRENT

AND

T

OTALS

> LCV

LCV

(Line Code Violation) - A Line Code Violation is defined as a Bipolar Violation (BPV), not including

the B8ZS code word if B8ZS is employed. The number displayed is

LCV

events, which is defined as one or

more BPVs in a one-second interval.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

URRENT

AND

T

OTALS

> SLP

SLP (Slip Error Event) - This occurs when a received frame is either repeated or deleted. A

SLP

error

indicates a timing problem.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

URRENT

AND

T

OTALS

> UAS

UAS

(Unavailable Seconds) - When 10 consecutive

SES

s have been logged, the unit is declared in an

unavailable state, the 10

SES

s are cleared, and the Unavailable Seconds count begins to increment starting

with 10. The unavailable state is cleared when 10 consecutive non-SES seconds have occurred.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> E

XTENDED

Provides statistics for the last 24 hours (in 15 minute windows) on key performance measures as specified
in ANSI T1.403 and AT&T TR 54016 for each of the T1 ports. Refer to the

C

URRENT

AND

T

OTALS

performance information for more details on listed statistics.

I

NTERFACES

(DSX) > S

TATUS

> P

ERFORMANCE

> C

LEAR

C

URRENT

D

ATA

Clears all statistics collected in the

C

URRENT

AND

T

OTALS

statistics table.