beautypg.com

Table 2, Instructions for changing passwords – ADTRAN 600R User Manual

Page 54

background image

Section 4 User Interface Guide

Total Access 600 Series System Manual

52

© 2004 ADTRAN, Inc.

61200624L1-1B

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> CRAFT P

ORT

> I

DLE

T

IME

This option defines the amount of time in minutes user may stay connected without any activity on the

CRAFT

port before the user is automatically logged out of the system. A value of

0

disables this inactivity

timer function enabling users to stay connected until manually logged out. The value range is

0

(def) to

255

(minutes).

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> CRAFT P

ORT

> B

AUD

R

ATE

This is the asynchronous rate that the

CRAFT

port will run. The possible values are

300, 1200, 2400, 4800,

9600, 19200, 38400

,

57600,

and

115200

. The default value is

9600

. The unit and the VT100 terminal or

PC with terminal emulation software must be set for the same baud rate.

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> CRAFT P

ORT

> D

ATA

B

ITS

The number of data bits that the

CRAFT

port sends in a frame. The possible values are

7

or

8

(def) bits. The

unit and the VT100 terminal or PC with terminal emulation software must be set for the same number of data
bits.

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> CRAFT P

ORT

> P

ARITY

This is the asynchronous parity that the

CRAFT

port will run. The possible values are

N

ONE

(def),

O

DD

, or

E

VEN

. The unit and the VT100 terminal or PC with terminal emulation software must have the same parity

setting.

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> CRAFT P

ORT

> S

TOP

B

ITS

This is the number of stop bits used for the

CRAFT

port. The possible values are

1

(def),

1.5

or

2

. The unit

and the VT100 terminal or PC with terminal emulation software must have the same number of specified
stop bits.

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> T

ELNET

A

CCESS

Activate the Telnet access and set up the various Telnet parameters from this menu. The Total Access 6XX
supports up to five simultaneous Telnet sessions.

Table 2. Instructions for Changing Passwords

Step

Action

1

Select the P

ASSWORD

field—a new P

ASSWORD

field displays.

2

Type the new password in the E

NTER

field.

3

Type the new password again in the C

ONFIRM

field.

The Total Access 6XX ships with default Telnet Access parameters of: guest (user),
password (password). Change this password during the initial configuration to protect
your unit.

This manual is related to the following products: