1. Connect to the Total Access 6XX using the CRAFT (RJ-48) port on the back of the Total Access 6XX.

If you are not already connected to the unit’s rear

CRAFT

interface, either with a VT100 compatible

terminal or with a PC running VT100 emulation software, follow the procedure in DLP-1, Connecting a
VT100 Terminal or PC to the CRAFT Port
. Connecting to the

CRAFT

interface limits the configuration

transfer procedure to

X

MODEM

only.

2. Log in to the unit.

3. Go to the S

YSTEM

U

TILITY

menu and select C

ONFIGURATION

T

RANSFER

menu; press .

4. Set the T

RANSFER

M

ETHOD

menu to X

MODEM

.

5. Select S

AVE

C

ONFIG

R

EMOTELY

to start the transfers. Enter Y to confirm the transfer and prepare the

Total Access 6XX for the transfer download.

The following message is displayed: This will begin sending a copy of the current system
configuration.

6. Configure the VT100 terminal or terminal emulation software to R

ECEIVE

(and prompt for a filename).

7. View the C

URRENT

T

RANSFER

S

TATUS

to verify the progress of the current transfer.

8. From the terminal emulation software, begin the XMODEM transfer by using the appropriate command

sequence. For Windows HyperTerminal, select T

RANSFER

>R

ECEIVE

F

ILE

. Enter the filename (including

path) and select XMODEM as the transfer method.

If necessary, refer to the terminal emulation software documentation for help.

Because XMODEM data is being transferred inband through the menu interface, the VT100 menus of
the Total Access 6XX will be inoperable from the

CRAFT

interface. You can cancel the update at any

time within the terminal emulation software. (Please consult the documentation provided by the
terminal emulation software to determine how to do this.)

9. When the transfer has successfully completed, I

DLE

displays in the C

URRENT

T

RANSFER

S

TATUS

field

and XMODEM D

OWNLOAD

C

OMPLETE

displays in the P

REVIOUS

T

RANSFER

S

TATUS

field.

Perform the following steps in the order listed.

When specifying the filename, ensure that the saved file has a .cfg extension;
otherwise, the file may not be available for uploading into other Total Access 6XX
units.