beautypg.com

Teledyne LeCroy WaveStation Waveform Generator Operators Manual User Manual

Page 48

background image

WaveStation

42

922700-00 Rev A

Sweep Operation menu selections and parameters include SwpTime,
StopFreq, FreqSpan, StartFreq, MidFreq, Source, TrigOut, Linear/Log, and
Direction as follows:

SwpTime - This parameter sets the overall sweep time span in which the
frequency changes from specified start frequency to stop frequency
values.

StopFreq - Provide a specific frequency value where the sweep must
end.

FreqSpan - Provide an overall span or range in which the sweep must
remain.

StartFreq - Provide a specific frequency value where the sweep is to
begin.

MidFreq - Specify a frequency where the center of the sweep must
remain.

Source - Select Internal, External, or Manual. If External is selected, use
the Trig/Gate/Fsk/Burst connector on the Back Panel. You can also
select Manual and specify exact start and stop times.

TrigOut - Select Off or Open. Open sets trigger on the rising edge of the
waveform.

Linear/Log - Press this operation button to highlight and select either
Linear or Log spacing for your sweep waveform.

Direction - Press this operation button to toggle between an upward
(↑)
or downward (↓) sweep direction for your waveform.