88
Chief User’s Manual
CATC
Version 1.7
Step 3
You can regenerate the frame numbers and to remove NAKed
transactions.
Once the generator text file is exported, you may need to edit the file and adjust
idle time to properly anticipate the responses from your device.
Data
Export packets in Data format if you need only the information contained in Data
blocks.
To export Data, follow these steps:
Step 1
From the File menu, select Export then Data.
The Export Data window appears.
Step 2
Enter the requested information.
•
Addr and EndP
Enter the address and endpoint as decimal values to export data from
a specific device. When the EndP is left blank, data from all the
endpoints of the device address are included.
•
Specify Token PIDs
Indicate a token to export data specific to a transaction type.
•
Acknowledgments
Qualify Handshake—Indicate a transaction with a qualified
handshake to export the correct data.
- ACK—Export acknowledged data
- NAK—Export data not acknowledged
- none—Export isochronous data with no handshake
•
Don’t Print Data Headers
Data packets are normally demarcated by text headers that indicate
the packet number and other transaction information. Use this option
to export data without these text headers only when a specific
address, endpoint, and token transaction are indicated.
•
Save Options