Teledyne LeCroy USB Chief - Users Manual User Manual
Page 124

116
Merlin Protocol Analyzer User’s Manual
CATC
Version 1.7
Table 5: External Interface Breakout Board: Pin Description
You can use pins 6-10 on the Breakout Board as Trigger Inputs for the Analyzer
from your hardware. If you hook up any of these pins, you must check the
corresponding Trigger Input number in this Recording Options Event Group to
enable it as a Trigger.
You can enable or disable Trigger Inputs 0 through 4 from the Breakout Board.
These inputs may also be set as Active-Low or Active-High signals.
Note
When you use the Active-High setting, the Analyzer internally pulls up the
Trigger input signals on the Breakout Board. Your External Trigger source
should drive the input signal low before starting to record or the Analyzer
immediately detects a Trigger Event because of the signal pull-ups.
Pin
Signal Description
1
GND
Signal Ground
2
GND
Signal Ground
3
+5V
5V DC source, limited internally to 500mA (polyswitch fuse)
4
TRIGGER OUT
Active-low TTL output
5
SPARE
Not connected
6
IN 0
Trigger/signal TTL input—programmable as active high or low
7
IN 1
Trigger/signal TTL input—programmable as active high or low
8
IN 2
Trigger/signal TTL input—programmable as active high or low
9
IN 3
Trigger/signal TTL input—programmable as active high or low
10
IN 4
Trigger/signal TTL input—programmable as active high or low
11
TRIGGER IN
Trigger input—programmable as active high or low
12
RESERVED 1
Reserved for future enhancement
13
RESERVED 2
Reserved for future enhancement
14
OUT 0
Signal TTL output—programmable as pulse high/low or toggle
15
OUT 1
Signal TTL output—programmable as pulse high/low or toggle
16
OUT 2
Signal TTL output—programmable as pulse high/low or toggle
17
OUT 3
Signal TTL output—programmable as pulse high/low or toggle
18
OUT 4
Signal TTL output—programmable as pulse high/low or toggle
19
OUT 5
Signal TTL output—programmable as pulse high/low or toggle
20
GATED VP
USB D+ signal—output after buffering
21
GATED VM
USB D- signal—output after buffering
22
GND
Signal Ground
23
GND
Signal Ground
BP
1
CURRENT MEASURE
+
Banana plug for optionally measuring the current of the USB Device
connected to the Record & Generate port of the Analyzer
BP
2
CURRENT MEASURE
–
Banana plug for optionally measuring the current of the USB Device
connected to the Record & Generate port of the Analyzer
n/a
9 by 31 plated through
holes
Prototype rework area; Top row connected to +5V; Bottom row
connected to GND; Remaining holes are not connected