beautypg.com

Usb current measure, Prototype rework area, Usb current measure prototype rework area – Teledyne LeCroy USB Chief - Users Manual User Manual

Page 123

background image

115

Chief User’s Manual

CATC

Version 1.7

Check a Trigger under On/Off to start a recording that continues until the
buffer is full

OR

Check a Trigger under Signal Continuously to instruct the Analyzer to keep
recording until you stop it.

Set the Trigger Output format:

Select Pulse High to trigger when the signal goes up.

Select Pulse Low to trigger when the signal goes down.

Select Toggle to trigger when there is a signal change, regardless of

whether it goes up or down.

USB Current Measure

The USB Chief can measure the current of a device. The Breakout Board contains
a convenient place to measure the USB current being used by the device
connected to the Record & Generate port.

To measure the USB current, follow these steps:

Step 1

Insert a current meter in series on the current measurement terminals of
the Breakout Board.

Step 2

Select ON for Current Measure in the Power and Connection window
under Setup on the Menu Bar.

Prototype Rework Area

The Breakout Board contains a prototype rework area for making custom circuits
for rapid development. The area consists of plated-through holes, 9 columns wide
by 31 rows long. The top row of holes is connected to +5V and the bottom row is
connected to GND. The remaining holes are not connected. Use the rework area
to insert custom components and wire-wrap their respective signal, power, and
ground pins.