Message area – IAI America RCA-E User Manual
Page 51
P. 48
9. Message Area
Code
Error Description
Common Solutions
10C
Motorola S Address Error
Abnormal Update program file (during update)
10D
Motorola S File Name Error
Abnormal update program file (during update)
10E
Timing Limit (W) (S)
Please check the TB-CPU Board Flash ROM Address setting DIP-SW (during update).
10F
Timing Limit (E) (S)
Please check the TB-CPU Board Flash ROM Address setting DIP-SW (during update).
111
Timing Limit (P) (S)
Please check the TB-CPU Board Flash ROM Address setting DIP-SW (during update).
112
Input Incorrect Error
Input value is incorrect. Please input allowable data.
113
Input Under Error
Input value is too small. Please input allowable data.
114
Input Over Error
Input value is too big. Please input allowable data.
115
Homing Incomplete
Moved before home complete.
116
Last Position Data Exists
During position add, please clear or delete the last position data.
117
No Move Data
Moving position data does not exist. Please assign position data.
118
Non-connect Axis Select
Non-connected axis is selected (this is not an error).
119
TB Paramater Rotation Over
The TB internal parameter change allowable rotation number exceeds after update.
11A
Flash Verify Error: S
Please check the TB-CPU Board Flash ROM Address setting DIP-SW (during update).
11B
Flash ACK Time Out: S
11C
Flash Verify Error: M
11D
Flash ACK Time Out: M
11E
Pair Data Mismatch
Data values are not consistent ( i .e. one (+) is smaller than sone (-1) ).
11F
Absolute Value Error
The absolute value of the input value is too small.
120
Initialize factor error
Factor data input data during controller initialization is abnormal. Please input allowable
data.
121
Push search end over
Push final destination point has an excessive stroke. Please modify the position or
positioning width.
122
Allocate, multi-axes connect
Axis Number allocate must be done with 1 axis
180
Change to axis number OK
(Not an error)
181
Controller initialize OK
(Not an error)