Avaya Media Gateway G350 User Manual
Page 110

Chapter 7
100
Avaya G350 Manager User Guide
2. Modify the parameters you want to change using the fields at the
bottom of the dialog box.
3. Click
Apply
. The DLCI parameters are modified.
To delete a DLCI:
1. Click the DLCI you want to delete.
2. Click
Delete
. A confirmation dialog box opens.
3. Click
Yes
.
4. Click
Apply
. The DLCI is deleted.
The following table provides a list of the fields in the DLCIs tab of the USP
dialog box and their descriptions:
Table 7-13. USP Dialog Box - DLCIs Parameters
Field
Description
DLCI
The DLCI for the circuit.
Type
The method used to create the DLCI. Possible
methods include:
• Local - The DLCI was created manually.
• Unused - The DLCI was created using
the LMI interface.
Status
The operational status of the DLCI. Possible
statuses include:
• Active - The DLCI is active.
• Inactive - The DLCI is inactive.
• Deleted - The DLCI has been deleted.
• Invalid - The DLCI is not valid.
Sub Interface
The Sub-Frame-Relay interface associated
with the DLCI.
Priority
The priority of traffic on the selected DLCI.
Possible priorities include:
• Primary
• High
• Medium
• Normal
• Low