beautypg.com

Fluid Components International GF03 User Manual

Page 7

background image

Doc. No. 06EN003352 Rev. B

3

Model GF03 Flow Meter

FLUID COMPONENTS INTERNATIONAL LLC http://www.fluidcomponents.com

FLOW TRANSMITTER

Operating Temperature: 0 to 140°F [-18 to 60°C]

Input Power: 115 Vac ± 15 V; 230 Vac ± 30 V; 22 to 30 Vdc; 23 Watts Max.

Output Signal

Analog:
Two independent, AC power isolated, which can be set as follows:

4-20 mA, 600 ohm maximum load

0-10 Vdc, 5000 ohm minimum load

0-5 Vdc, 2500 ohm minimum load

1-5 Vdc, 2500 ohm minumum load

One optional pressure output:

4-20 mA, 600 ohm maximum load

One gas compensator output:

4-20 mA, 600 ohm maximum load.

Two programmable 10 amp (115 Vac or 24 Vdc) relay switch points.

Communication Port: EIA-232 [RS-232C]

Display: 4 line/20 character per LCD line, indicating flow rate and process temperature
and/or totalized flow.

Communicator(optional): Hand held plug-in interface (model FC88).

Remote Enclosure

Standard: NEMA/CSA Type 4X (equivalent to IP66) Fiberglass
Option: Aluminum rated for hazardous location use Class I and II, Division 1 and 2,
Group B, C, D, E, F, G (previously referred to as NEMA 7 and EEx d IIB) resists the
effects of weather and corrosion.