beautypg.com

B&K Precision 2552-2559 - Programming Manual User Manual

Page 76

background image

76

DESCRIPTION

The PARAMETER_CUSTOM command

controls the parameters that have customizable
qualifiers.

Note: The measured value of a parameter setup

with PACU may be read using PAVA?

COMMAND SYNTAX

PArameter_CUstom ,

, : = 1 to 5

: ={PKPK, MAX, MIN, AMPL,
TOP, BASE, CMEAN, MEAN, RMS, CRMS,
OVSN, FPRE, OVSP, RPRE, PER, FREQ,
PWID, NWID, RISE, FALL, WID, DUTY,
NDUTY }

: = Measurement qualifier specific
to each(source option)


QUERY SYNTAX

PArameter_CUstom?


RESPONSE FORMAT

PArameter_Custom , ,


EXAMPLE

Command Example PACU 2, PKPK, C1

Query/Response Examples PACU? 2 returns:
PACU 2, PKPK, C1
PAVA? CUST2 returns:
C2: PAVA CUST2, 160.00mV


RELATED

COMMANDS PARAMETER_CLR,

PARAMETER_VALUE

CURSOR

PARAMETER_CUSTOM, PACU

Command /Query