DESCRIPTION

The WAIT command prevents the instrument

from analyzing new commands until the
oscilloscope has completed the current
acquisition.

The instrument will be waiting for trigger or the
limit time over (if we set it) or the device time
out when we sent this command


COMMAND SYNTAX

WAIT

Note : This command have two ways to use. One
sets the limited time, another one doesn’t set the
limited time.


EXAMPLE

If we move the trigger level of the source to the

position where the trace isn’t triggered. Then we
send an ARM command to set the trigger mode
to single. Finally we send the WAIT command.
The instrument will be waiting for triggering
until the time over (if we set it) or time out.

If we move the trigger level of the source, and
the instrument is triggered. Then we send an
ARM command to set the trigger mode to single.
Finally we send the WAIT command. The
WAIT command will be finished if we send a
FRTR for triggering.