Low Pass

The low pass filter is the opposite of the high pass filter. All frequencies above the
specified frequency are attenuated allowing lower frequencies to pass.
The default cutoff is 10 kHz.

Figure 26.

Low Pass Filter Response Curve

Here, the frequencies higher than the specified frequency, 10 kHz, are attenuated leaving
the lower frequency response flat.