command and response table for Basic sis commands (continued)

command

ascii command

(host to device)

response

(device to host)

additional

description

serial Port

Send Data String

E

1

*

X1&

*

X2)

*

X2!

RS

}X@

response

]

Configure parameters

E

1

*

X2%

,

X2^

,

X2&

,

X2*

CP

}

Cpn1

Ccp

X2%

,

X2^

,

X2&

,

X2*]

View serial port parameters

E

1CP

}

X2%

,

X2^

,

X2&

,

X2*

]

Configure rcv timeout

E

1

*

X1&

*

X2)

*

X2#

*

X2!

CE

}

Cpn1

Cce

X1&

,

X2)

,

X2#

,

X2!

]

View receive timeout

E

1CE

}

X1&

,

X2)

,

X2#

,

X2!

]

Digital i/o Port

View I/O mode

X!

[

X4)

]

View I/O state

X!

]

X4#

]

notEs:

X!

= Port Number

01 to 99 up to maximum digital ports

X@

= Command data section

For web encoding only: Data will be directed to specified port and

must

be

encoded if non-alpha numeric. Since data can include either command

terminator, they must be encoded as follows when used within the data section:

Space (Hex:

20

) is encoded as

%20

and Plus sign (Hex:

2B

)

is encoded as

%2B.

X1&

= Command string wait time

0-32767 in tens of milliseconds

X2)

= Character wait time

0-32767 in tens of milliseconds

X2!

= Length of stream or delimiter

L=Byte Count (00 – 32767), D=decimal value for ASCII character

(0-00255)

X2#

= Priority status for receiving timeouts (Default=0)

0

=Send data string command parameters if they exist

1

=Configure receive timeout command parameters instead.

X2%

= Baud Rate (Default=9600)

300,600,1200,1800,2400,3600,4800,7200,9600,14400,19200

38400,57600,115200

X2^

= Parity (Default=N=none)

O=odd

E=even

N=none

M=mark

S=space

X2&

= Data bits

7, 8 (Default=8)

X2*

= Stop bits

1, 2 (Default=1)

X4)

= I/O mode

0

=Input

1

=Output

X4#

= I/O state

0

=Off

1

=On

DMP 128 • SIS Programming and Control