Extron Electronics DMP 128 User Guide User Manual
Page 144
command and response table for Basic sis commands (continued)
command
ascii command
(host to device)
response
(device to host)
additional
description
serial Port
Send Data String
E
1
*
X1&
*
X2)
*
X2!
RS
}X@
response
]
Configure parameters
E
1
*
X2%
,
X2^
,
X2&
,
X2*
CP
}
Cpn1
•
Ccp
X2%
,
X2^
,
X2&
,
X2*]
View serial port parameters
E
1CP
}
X2%
,
X2^
,
X2&
,
X2*
]
Configure rcv timeout
E
1
*
X1&
*
X2)
*
X2#
*
X2!
CE
}
Cpn1
•
Cce
X1&
,
X2)
,
X2#
,
X2!
]
View receive timeout
E
1CE
}
X1&
,
X2)
,
X2#
,
X2!
]
Digital i/o Port
View I/O mode
X!
[
X4)
]
View I/O state
X!
]
X4#
]
notEs:
X!
= Port Number
01 to 99 up to maximum digital ports
X@
= Command data section
For web encoding only: Data will be directed to specified port and
must
be
encoded if non-alpha numeric. Since data can include either command
terminator, they must be encoded as follows when used within the data section:
Space (Hex:
20
) is encoded as
%20
and Plus sign (Hex:
2B
)
is encoded as
%2B.
X1&
= Command string wait time
0-32767 in tens of milliseconds
X2)
= Character wait time
0-32767 in tens of milliseconds
X2!
= Length of stream or delimiter
L=Byte Count (00 – 32767), D=decimal value for ASCII character
(0-00255)
X2#
= Priority status for receiving timeouts (Default=0)
0
=Send data string command parameters if they exist
1
=Configure receive timeout command parameters instead.
X2%
= Baud Rate (Default=9600)
300,600,1200,1800,2400,3600,4800,7200,9600,14400,19200
38400,57600,115200
X2^
= Parity (Default=N=none)
O=odd
E=even
N=none
M=mark
S=space
X2&
= Data bits
7, 8 (Default=8)
X2*
= Stop bits
1, 2 (Default=1)
X4)
= I/O mode
0
=Input
1
=Output
X4#
= I/O state
0
=Off
1
=On
DMP 128 • SIS Programming and Control
138