beautypg.com

Extron Electronics DMP 128 User Guide User Manual

Page 120

background image

4.

In the Unit Name: field, enter a descriptive name for the DMP 128 (typically the

device name and location) to enable easy identification on the network (see figure 68).

DMP128-ConfRoom1

Unit name can be up to 24 characters drawn from the

alphabet (A-Z), digits (0-9), and minus sign/hyphen (-).

No spaces are permitted and it is not case sensitive.

The first character must be an alpha character. The last

character must not be a minus sign/hyphen.

Figure 68.

Device Settings - Unit Name

5.

Click Apply, then OK to close the dialog box.

6.

Open the Dante Controller (see

Start Dante Controller

on page 118).

7.

From the Dante Controller menu bar, select Device > Device View (see

Rename

a Dante Device

on page 120).

8.

Choose the device. The DMP 128 appears as DMP128, plus the last six digits of the

Dante MAC address.

notE: Connect DMP 128 units to the Dante network one at a time to easily

identify which one is being named. To confirm the proper device, compare
the Dante MAC address printed on the rear panel of the unit with the MAC
address shown in figure 68.

9.

Select the Device Config tab in Dante Controller.

10.

Rename the device to match the DSP 128 name given in DSP Configurator (see
step 4 above), then press .

11.

Select Yes to confirm the new name.

12.

To connect additional DMP 128s, repeat this procedure with the next device.

DMP 128 • Software Control

114