sis Programming
and control

This section describes SIS programming and control of the DMP 128, including:

Connection Options

Host-to-device Communications

Command and Response Tables

connection options

The DMP 128 Digital Matrix Processor can be remotely connected via a host computer
or other device (such as a control system) attached to the rear panel RS-232 port or LAN
port, or the front panel USB Config port.
The DMP 128 can be set up and controlled using SIS commands, embedded Web
pages, or DSP Configurator software. See

Installation

on page 5 for pin assignments

and details on the configuration and control port connections. For information on
DSP Configurator, see

DmP Software

on page 12 and for the embedded Web pages,

see

HTmL Operation

on page 155.

SIS commands can be executed using the Extron Electronics DataViewer program, found
on the Software Products DVD included with the product.
DmP 128 RS-232 protocol:

38400 baud

no parity

1 stop bit

8 data bits

no flow control

notE: The rear panel configuration port requires 38400 baud communication. This

is a higher speed than many other Extron products use. The DMP 128 control
software automatically sets the connection for the appropriate speed. When using
DataViewer or similar application, make sure the PC or control system connected
to the port is set for 38400 baud.

See

RS-232 Port

on page 130, for additional details on connecting the RS-232 port.

USB port details:
The Extron USB driver must be installed before use (see

Installing the USB Driver

on

page 15).
LAN port defaults:
DMP 128 IP address: 192.168.254.254
Gateway IP address: 0.0.0.0
Subnet mask:

255.255.0.0

DHCP:

off

DMP 128 • SIS Programming and Control